Water Quality, Metals & Mixed Environmental Practice
Water-quality, BOD and heavy-metal numerics — this set contains no LCA questions.
Assessment Overview: 5 multiple-choice questions assessing conceptual and mathematical proficiency in Water Quality, Metals & Mixed Environmental Practice.
Practice Questions & Answers
Question 1: A sample contains 1.58 mg/L of arsenic. The WHO guideline is 10 µg/L. How many times the limit is this?
- A. 158 times the WHO limit (Correct Answer)
- B. 79 times the WHO limit
- C. 15.8 times the WHO limit
- D. 159 times the WHO limit
Pedagogical Explanation: 1.58 mg/L = 1580 µg/L. 1580 ÷ 10 = 158 times the WHO limit of 10 µg/L for arsenic.
Question 2: A process makes 5 kg of product and generates 186 kg of waste. What is the E-factor?
- A. 38
- B. 19
- C. 37 (Correct Answer)
- D. 0
Pedagogical Explanation: E-factor = mass of waste / mass of product = 186/5 = 37. Lower is greener; pharma processes are typically 25–100.
Question 3: Winkler titration: 7.5 mL of 0.025 N Na₂S₂O₃ used for a 200 mL sample. Dissolved oxygen?
- A. 3.8 mg/L
- B. 7.5 mg/L (Correct Answer)
- C. 11.3 mg/L
- D. 15 mg/L
Pedagogical Explanation: DO = V(thio) × N × 8000 / V(sample) = 7.5 × 0.025 × 8000/200 = 7.5 mg/L.
Question 4: In the chlor-alkali cell, chlorine is discharged at the:
- A. diaphragm
- B. membrane
- C. anode (Correct Answer)
- D. cathode
Pedagogical Explanation: Oxidation at anode: 2Cl⁻ → Cl₂ + 2e⁻; H₂ at cathode.
Question 5: Which technique is best for pH measurement?
- A. glass pH electrode (Correct Answer)
- B. UV-visible spectrophotometry
- C. ICP-MS
- D. atomic absorption spectroscopy (AAS)
Pedagogical Explanation: glass pH electrode is the standard method for pH measurement.