13C NMR: Ranges, Symmetry and Decoupling
Carbon shift ranges, signal counting, decoupling, natural abundance and DEPT.
Assessment Overview: 5 multiple-choice questions assessing conceptual and mathematical proficiency in 13C NMR: Ranges, Symmetry and Decoupling.
Practice Questions & Answers
Question 1: 13C spectra are not routinely integrated because
- A. all peaks are equal
- B. they have no signals
- C. integration is forbidden
- D. NOE enhancement makes peak areas unreliable (Correct Answer)
Pedagogical Explanation: Unequal nuclear Overhauser enhancements distort 13C peak areas.
Question 2: Quaternary carbons in proton-decoupled 13C NMR
- A. appear as quartets
- B. are absent
- C. disappear with D2O
- D. appear as singlets (Correct Answer)
Pedagogical Explanation: With no attached protons and decoupling applied, each gives one singlet.
Question 3: In 13C NMR, alkene carbons typically appear at
- A. 100-150 ppm (Correct Answer)
- B. 10-25 ppm
- C. 50-80 ppm
- D. 190-220 ppm
Pedagogical Explanation: sp2 Alkene carbons appear at 100-150 ppm.
Question 4: 13C is less sensitive than 1H mainly because of
- A. solvent interference
- B. its high abundance
- C. low natural abundance and a smaller magnetic moment (Correct Answer)
- D. the lack of a magnet
Pedagogical Explanation: 1.1 percent abundance plus a lower gyromagnetic ratio makes 13C about 6000x less sensitive.
Question 5: A method is linear from 4.9 to 98 ppm with acceptable precision/accuracy. Its validated range is:
- A. 98 ppm and above
- B. 0-196 ppm
- C. 4.9-98 ppm (Correct Answer)
- D. 4.9 ppm only
Pedagogical Explanation: Range = the tested interval with acceptable precision, accuracy AND linearity.