Nernst Distribution Law: Iodine between Water and Tetrachloromethane
To determine the partition coefficient of iodine between water and CCl4 and verify the Nernst distribution law.
Theoretical Foundations
At equilibrium, K_D = [I2]_CCl4/[I2]_water (same molecular species in both phases). Shaking iodine with the two immiscible solvents, separating, and titrating the aqueous layer with thiosulphate (I2 + 2S2O3²- -> 2I- + S4O6²-) gives [I2]_water; [I2]_CCl4 follows from mass balance. K_D should be constant across concentrations.
Required Apparatus & Chemicals
Laboratory Apparatus
- Separating funnels (3)
- Burette
- Pipettes
- Conical flasks
- Balance
Chemical Reagents
- Iodine solution in CCl4 (prepared, ~0.05 M)
- Tetrachloromethane
- Distilled water
- Sodium thiosulphate (0.01 mol/dm³)
- Starch indicator
Step-by-Step Practical Procedure
- Shake 25.0 cm³ iodine/CCl4 solution with 50.0 cm³ water in a funnel for 5 min; allow to separate.
- Run off the aqueous layer; pipette 25.0 cm³; titrate with 0.010 M thiosulphate (starch near end).
- [I2]_water = (V_thio × 0.010)/(2 × 0.025).
- Repeat with different initial iodine concentrations.
- Compute K_D for each; check constancy.
Observations & Expected Results
Typical student data: K_D ≈ 85 (iodine strongly prefers CCl4 — the organic layer stays deep violet while the aqueous layer is pale yellow).
Worked Stoichiometric Calculations
Problem: Typical student data: 25.0 cm³ aqueous layer needs 2.90 cm³ of 0.010 M Na2S2O3. Initial: 25.0 cm³ of 0.050 M I2 in CCl4 shaken with 50.0 cm³ water. Find K_D.
Working: n(S2O3) = 0.00290 × 0.010 = 2.90×10⁻⁵ mol → n(I2) in 25 cm³ = 1.45×10⁻⁵ mol → [I2]_water = 5.80×10⁻⁴ M. Total I2 = 0.025 × 0.050 = 1.25×10⁻³ mol; in water: 0.050 × 5.80×10⁻⁴ = 2.90×10⁻⁵ mol; in CCl4: 1.221×10⁻³ mol → [I2]_CCl4 = 0.0488 M. K_D = 0.0488/5.80×10⁻⁴ = 84.2 ≈ 84 (literature ≈ 85).
Safety Precautions & Hazard Control
- Supervision: CCl4 is toxic and a suspected carcinogen — use in a fume cupboard, minimal volumes.
- Iodine stains; wear gloves.
- Vent separating funnels when shaking.
Waste Disposal Protocol
Halogenated organic waste container for CCl4 layers; aqueous thiosulphate to drain.
Viva Voce Oral Defense Questions & Answers
Q: State the Nernst distribution law.
A: At constant T, a solute distributes between two immiscible solvents so that the ratio of concentrations (of the same molecular species) is constant.
Q: Why must the molecular species be the same?
A: If iodine associated or dissociated differently in one phase, the simple ratio would vary with concentration — the law applies per species.
Q: Why titrate the aqueous layer, not the organic?
A: Thiosulphate titration is aqueous; the organic concentration follows by mass balance.