Ebullioscopy I: Determining Kb of Water with Glucose
To determine the ebullioscopic constant of water from the boiling-point elevation caused by glucose.
Theoretical Foundations
ΔT_b = K_b·m, with K_b(water) = 0.512 °C·kg/mol. Boiling 100 g water with dissolved glucose under a reflux-style setup (to avoid concentration drift) gives ΔT_b; K_b = ΔT_b/m. Precise thermometry is essential since elevations are small.
Required Apparatus & Chemicals
Laboratory Apparatus
- Round-bottom flask
- Reflux condenser
- Thermometer (0.1 °C)
- Heating mantle
- Balance
- Boiling chips
Chemical Reagents
- Glucose (AR grade)
- Distilled water
Step-by-Step Practical Procedure
- Boil 100.0 g distilled water under reflux; record T_b(pure).
- Add 5.00 g glucose (0.0278 mol); re-equilibrate; record T_b.
- ΔT_b = difference; m = 0.278 mol/kg.
- K_b = ΔT_b/m.
- Compare with 0.512 °C·kg/mol.
Observations & Expected Results
Typical student data: ΔT_b = 0.14 °C → K_b = 0.50 °C·kg/mol; the small elevation demands careful reading.
Worked Stoichiometric Calculations
Problem: Typical student data: 5.00 g glucose (0.0278 mol) in 100.0 g water, ΔT_b = 0.14 °C. Find K_b.
Working: m = 0.278 mol/kg. K_b = 0.14/0.278 = 0.504 °C·kg/mol ≈ accepted 0.512 °C·kg/mol.
Safety Precautions & Hazard Control
- Supervision: boiling water/steam burns; heating mantle safety.
- Always use boiling chips to prevent bumping.
- Keep the condenser water flowing.
Waste Disposal Protocol
Glucose solution to drain.
Viva Voce Oral Defense Questions & Answers
Q: Why is a condenser used?
A: To return evaporated water, keeping the solution concentration (and hence molality) constant during boiling.
Q: Why is ΔT_b so small?
A: K_b of water is only 0.512 °C·kg/mol — precise thermometry or a Beckmann thermometer is needed.
Q: Why doesn't glucose affect the vapour?
A: It is non-volatile, so only water contributes to vapour pressure; the solute merely dilutes the solvent.