CHEMVEN

Specific Heat Capacity of Lead Shot: Handling a Small ΔT

To measure the low specific heat capacity of lead and practise working with small temperature changes.

Level: UniversitySafety: SafeTime: 60 min
Aim of Experiment: To measure the low specific heat capacity of lead and practise working with small temperature changes.

Theoretical Foundations

Lead's c (0.129 J/g·°C) is the lowest of common metals, so ΔT is small and measurement precision dominates the error. This experiment teaches error propagation: a ±0.1 °C thermometer error on a 2.6 °C rise is already ±4%.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Polystyrene cup with lid
  • Lead shot (~200 g) in a gauze bag
  • Boiling water bath
  • Thermometer (0.1 °C)
  • Balance
  • Measuring cylinder

Chemical Reagents

  • Distilled water

Step-by-Step Practical Procedure

  1. Weigh lead shot in the gauze bag; heat in boiling water 5 min.
  2. Place 150.0 g water at known T in the cup.
  3. Transfer the bag; stir; record T_eq carefully.
  4. Compute c_Pb.
  5. Estimate the percentage uncertainty from the thermometer resolution.

Observations & Expected Results

Typical student data: 200.0 g Pb, 150.0 g water at 20.0 °C, T_eq = 22.6 °C → c ≈ 0.105 J/g·°C (book 0.129).

Worked Stoichiometric Calculations

Problem: Typical student data: 200.0 g Pb at 100 °C into 150.0 g water at 20.0 °C; T_eq = 22.6 °C. Find c_Pb and comment on uncertainty.

Working: Water gains 150.0 × 4.18 × 2.6 = 1630 J. c_Pb = 1630/[200.0 × 77.4] = 0.105 J/g·°C. Thermometer ±0.1 °C on ΔT = 2.6 °C gives ≈ ±4% from that reading alone, plus transfer losses — hence the low result.

Safety Precautions & Hazard Control

  • Lead is toxic; do not handle shot with bare hands unnecessarily — wash hands after.
  • Do not overheat; lead melts at 327 °C (not reached here).
  • Boiling-water precautions.

Waste Disposal Protocol

Water to drain; keep lead shot for reuse, contained.

Viva Voce Oral Defense Questions & Answers

Q: Why is the percentage error larger here than for aluminium?

A: ΔT is much smaller, so the fixed thermometer resolution is a larger fraction of the reading.

Q: How would you reduce the error?

A: Use more lead, less water, or a more precise temperature sensor (thermocouple/data logger).

Q: Why is lead's c so low?

A: Heavy atoms: per gram there are few atoms, and heat capacity per atom is roughly constant (Dulong-Petit).