Enthalpy of Solution of Anhydrous Calcium Chloride
To measure the strongly exothermic ΔH_sol of CaCl2 and relate it to ion charge density.
Theoretical Foundations
Ca²+ has a high charge density, giving an extremely negative hydration enthalpy that overwhelms the lattice term. Hence anhydrous CaCl2 dissolves with a large heat release — the basis of self-heating packs and its use as a de-icer and desiccant (though the desiccant action is hydrate formation, also exothermic).
Required Apparatus & Chemicals
Laboratory Apparatus
- Polystyrene cup with lid
- Thermometer (0.1 °C)
- Balance
- Measuring cylinder
- Stirrer
Chemical Reagents
- Calcium chloride, anhydrous (AR grade)
- Distilled water
Step-by-Step Practical Procedure
- Place 100.0 g water in the cup; record T.
- Weigh 5.55 g anhydrous CaCl2 (0.050 mol).
- Add with stirring; record maximum T.
- q = 105.55 × 4.18 × ΔT; ΔH_sol = -q/0.050.
- Compare with NaCl and NaOH results; rank by cation charge density.
Observations & Expected Results
Typical student data: 21.5 °C → 30.4 °C (ΔT = +8.9 °C); rapid dissolution with strong warming.
Worked Stoichiometric Calculations
Problem: Typical student data: 5.55 g CaCl2 (0.050 mol) in 100.0 g water, ΔT = +8.9 °C. Find ΔH_sol.
Working: q = 105.55 × 4.18 × 8.9 = 3927 J. ΔH_sol = -3927/0.050 = -78.5 kJ/mol (literature ≈ -81.3 kJ/mol) — strongly exothermic due to Ca²+ hydration.
Safety Precautions & Hazard Control
- Use freshly dried anhydrous CaCl2; it hydrates rapidly in air.
- Solution is mildly irritant; eye protection.
- Add solid steadily to avoid clumping.
Waste Disposal Protocol
Calcium chloride solution to drain with water.
Viva Voce Oral Defense Questions & Answers
Q: Why is CaCl2 dissolution more exothermic than NaCl?
A: Ca²+ has double the charge and small radius, so its hydration enthalpy is far more negative.
Q: Why must the salt be anhydrous?
A: Any pre-formed hydrate has already released part of the hydration heat, giving a less exothermic result.
Q: Give two applications of this exothermicity.
A: Self-heating food/pain packs and de-icing (melting ice releases heat, accelerating melting).