Calorimeter Heat Capacity by the Method of Mixtures
To determine the heat capacity of a polystyrene-cup calorimeter so later enthalpy results can be corrected.
Theoretical Foundations
A real calorimeter absorbs part of the heat: q_lost_by_hot = q_gained_by_cold + C_cal·ΔT_cal. Mixing known masses of hot and cold water lets C_cal be found from the deficit between heat lost and heat gained. Corrected calorimetry then uses q = (mc + C_cal)ΔT.
Required Apparatus & Chemicals
Laboratory Apparatus
- Polystyrene cup with lid
- 250 cm³ beaker
- Two thermometers (0.1 °C)
- Measuring cylinder (100 cm³)
- Kettle or water bath
- Stirrer
Chemical Reagents
- Distilled water (hot and cold)
- Ice (optional, to cool water)
Step-by-Step Practical Procedure
- Place 50.0 g of cold water (≈20 °C) in the cup; record T_cold.
- Heat ~60 cm³ water to ≈60 °C; pour 50.0 g into a pre-warmed cylinder and record T_hot.
- Add hot water to the cup quickly, stir, record equilibrium T_eq.
- Compute heat lost by hot water and heat gained by cold water.
- C_cal = (q_lost - q_gained)/(T_eq - T_cold).
- Repeat and average.
Observations & Expected Results
Typical student data: T_hot = 60.0 °C, T_cold = 20.0 °C, T_eq = 38.5 °C (below the ideal 40.0 °C), giving C_cal ≈ 34 J/°C.
Worked Stoichiometric Calculations
Problem: Typical student data: 50.0 g water at 60.0 °C mixed with 50.0 g water at 20.0 °C; T_eq = 38.5 °C. Find C_cal.
Working: q_lost = 50.0 × 4.18 × (60.0 - 38.5) = 4493.5 J. q_gained = 50.0 × 4.18 × (38.5 - 20.0) = 3866.5 J. Difference absorbed by cup = 627 J over ΔT = 18.5 °C. C_cal = 627/18.5 = 33.9 J/°C.
Safety Precautions & Hazard Control
- Beware hot water scalds; handle with care.
- Transfer hot water quickly to minimise cooling in transit.
- Use the same cup and lid as in the enthalpy experiments.
Waste Disposal Protocol
Water to drain.
Viva Voce Oral Defense Questions & Answers
Q: Why is T_eq below 40.0 °C?
A: The calorimeter itself (cup, lid, thermometer) absorbs heat, and some heat escapes to the air.
Q: How does C_cal improve ΔH_neut results?
A: Using q = (mc + C_cal)ΔT accounts for heat taken by the apparatus, giving a larger, more accurate q.
Q: Why use equal masses of water?
A: It simplifies the arithmetic and makes the heat deficit easy to interpret, though any known masses work.