Fajan's Adsorption Indicators: Eosin in Argentometric Titration
To use eosin as an adsorption indicator in the titration of chloride with silver nitrate.
Theoretical Foundations
Before the end point, AgCl colloid adsorbs Cl^- (negative) and repels eosin anions. After the end point, excess Ag^+ makes the colloid positive, adsorbing eosin - its colour changes from yellow-green (solution) to pink on the precipitate surface, marking the end point.
Required Apparatus & Chemicals
Laboratory Apparatus
- Burette
- Conical flasks
- Pipette
- White tile
Chemical Reagents
- Sodium chloride (0.05 M)
- Silver nitrate (0.05 M)
- Eosin indicator (0.1%)
- Distilled water
Step-by-Step Practical Procedure
- Pipette 25 mL NaCl into a flask; add 5 drops eosin.
- Titrate with AgNO3 with vigorous swirling.
- Note the yellow-green solution with white AgCl precipitate.
- At the end point the precipitate suddenly turns pink.
- Record the titre; repeat for concordance.
Observations & Expected Results
Sharp change: the precipitate flashes pink within one drop at ~25.0 mL - as sharp as chromate indicator without its toxicity.
Worked Stoichiometric Calculations
Problem: 25.0 mL of 0.0500 M NaCl needs 24.8 mL AgNO3. Find the AgNO3 molarity.
Working: M_Ag = (25.0 x 0.0500)/24.8 = 0.0504 M.
Safety Precautions & Hazard Control
- Swirl vigorously - the indicator works on the precipitate surface.
- Silver nitrate stains; wear gloves.
- Titrate promptly; AgCl darkens in light.
Waste Disposal Protocol
Silver chloride residues to silver-recovery waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is the precipitate negative before the end point?
A: Excess Cl^- in solution adsorbs on AgCl (Paneth-Fajans rule), repelling eosin anions.
Q: What causes the pink colour?
A: Adsorbed eosin on positively charged AgCl after the end point - the dye's colour changes on adsorption.
Q: Why is eosin better than chromate here?
A: No toxic chromate; works in slightly acidic solution where Mohr's method fails.