CHEMVEN

Paper Chromatography of Inks: Partition and Adsorption on Cellulose

To separate the dyes in black ink by paper chromatography and calculate Rf values.

Level: UniversitySafety: SafeTime: 45 min
Aim of Experiment: To separate the dyes in black ink by paper chromatography and calculate Rf values.

Theoretical Foundations

Cellulose paper holds bound water (stationary phase); the rising solvent partitions/adsorbs dyes differentially. Each dye's Rf = distance moved/distance of solvent front characterises it - a surface/partition phenomenon.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Chromatography paper strips
  • Beaker with lid
  • Capillary tubes
  • Ruler
  • Pencil

Chemical Reagents

  • Black water-based ink / marker
  • Distilled water or ethanol-water (solvent)
  • Pure dye standards (optional)

Step-by-Step Practical Procedure

  1. Draw a pencil baseline 2 cm from the strip end.
  2. Spot black ink on the baseline; dry.
  3. Stand the strip in solvent below the baseline; cover the beaker.
  4. Let the front rise ~10 cm; mark it immediately.
  5. Measure spot centres; calculate Rf for each component.

Observations & Expected Results

Black ink splits into blue, red/pink and yellow spots with Rf ~ 0.3, 0.5, 0.7 - the 'single' colour is a mixture.

Worked Stoichiometric Calculations

Problem: Solvent front 10.0 cm; blue spot centre 3.2 cm, red spot 5.5 cm. Find both Rf values.

Working: Rf(blue) = 3.2/10.0 = 0.32; Rf(red) = 5.5/10.0 = 0.55.

Safety Precautions & Hazard Control

  • Spot small and concentrated - large spots smear.
  • Do not dip the baseline in solvent.
  • Mark the front before it dries.

Waste Disposal Protocol

Paper strips to general waste; solvent to organic waste if ethanol used.

Viva Voce Oral Defense Questions & Answers

Q: What is Rf?

A: Retardation factor: distance moved by solute divided by distance moved by solvent front.

Q: Why use a pencil, not pen, for the baseline?

A: Pen ink would dissolve and chromatograph itself, contaminating the result.

Q: How would a more polar solvent change Rf?

A: It competes better for adsorption sites, so all spots move further (higher Rf).

← Back to Experiments Directory