Effect of Light Intensity on a Photochemical Rate (Inverse-Square Law)

To verify that a photochemical reaction rate is proportional to light intensity using the inverse-square law.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: To verify that a photochemical reaction rate is proportional to light intensity using the inverse-square law.

Theoretical Foundations

For a point-like source, intensity I is proportional to 1/d^2. If the photochemical rate is proportional to I, then the rate at distance d1 vs d2 scales as (d2/d1)^2 - tested here with the photobleaching of a dye or H2O2 decomposition.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Lamp on an optical bench
  • Metre ruler
  • Matched sample tubes
  • Colorimeter
  • Stopwatch

Chemical Reagents

  • Methylene blue solution (dilute)
  • Titanium dioxide (optional catalyst)
  • Distilled water

Step-by-Step Practical Procedure

  1. Place identical dye samples at 20, 30 and 40 cm from the lamp.
  2. Irradiate all for the same time (30 min).
  3. Measure absorbance change in each.
  4. Calculate relative rates.
  5. Compare with (d_ref/d)^2 prediction.

Observations & Expected Results

Typical student data: relative rates 1.00 (20 cm) : 0.44 (30 cm) : 0.25 (40 cm) - matching 1 : (20/30)^2 : (20/40)^2 = 1 : 0.44 : 0.25.

Worked Stoichiometric Calculations

Problem: Rate at 20 cm is 0.020 min^-1. Predict the rate at 50 cm.

Working: Rate scales as 1/d^2: k_50 = 0.020 x (20/50)^2 = 0.020 x 0.16 = 3.2 x 10^-3 min^-1.

Safety Precautions & Hazard Control

  • Keep all samples at the same temperature (lamp heats).
  • Align samples at the same height as the lamp filament.
  • Do not look directly at a bright/UV lamp.

Waste Disposal Protocol

Dye solutions to coloured waste.

Viva Voce Oral Defense Questions & Answers

Q: Why does intensity follow 1/d^2?

A: Light spreads over a sphere of area 4·pi·d^2, so energy per unit area falls as 1/d^2.

Q: When would rate NOT be proportional to intensity?

A: At very high intensity, radical-radical termination becomes important and rate scales as sqrt(I).

Q: How is this used in actinometry?

A: Measuring rate at known distance calibrates unknown lamp intensities.