Surface Tension by Capillary Rise
To determine the surface tension of water and ethanol from the height of capillary rise.
Theoretical Foundations
A liquid rises in a capillary until the surface-tension force balances the liquid column's weight: 2·pi·r·gamma·cos(theta) = pi·r^2·h·rho·g. For clean glass and water, theta ~ 0, so gamma = (r·h·rho·g)/2.
Required Apparatus & Chemicals
Laboratory Apparatus
- Capillary tubes of known radius (microscope-calibrated)
- Beakers
- Travelling microscope or vernier scale
- Thermometer
- Stand and clamp
Chemical Reagents
- Distilled water
- Ethanol
- Chromic acid (cleaning)
- Detergent
Step-by-Step Practical Procedure
- Clean capillaries with chromic acid; rinse and dry.
- Measure the internal radius r with a travelling microscope.
- Dip the capillary vertically in water; measure rise height h from the flat surface.
- Repeat with ethanol.
- Calculate gamma = r·h·rho·g/2 for each liquid.
- Compare with stalagmometer values.
Observations & Expected Results
Typical student data: r = 0.025 cm, water h = 5.9 cm -> gamma ~ 72 dyn/cm; ethanol h = 1.9 cm -> gamma ~ 22 dyn/cm. Ethanol's lower rise is clearly visible.
Worked Stoichiometric Calculations
Problem: Capillary radius 0.0250 cm, water rise 5.90 cm, rho = 0.998 g/cm^3, g = 981 cm/s^2. Calculate gamma.
Working: gamma = (0.0250 x 5.90 x 0.998 x 981)/2 = (144.4)/2 = 72.2 dyn/cm - excellent agreement with 72.8 dyn/cm.
Safety Precautions & Hazard Control
- The tube must be scrupulously clean - grease gives a false contact angle.
- Measure h from the level of the flat liquid surface outside.
- Keep the capillary truly vertical.
Waste Disposal Protocol
Rinse water to drain; ethanol to organic waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is the contact angle assumed zero?
A: Clean glass is fully wetted by water, so the meniscus meets the wall tangentially (theta ~ 0).
Q: Why does mercury show capillary depression?
A: Mercury does not wet glass (theta ~ 140 C), so cos(theta) is negative and the meniscus is pushed down.
Q: Which method is more accurate, capillary rise or stalagmometer?
A: Capillary rise, if r is measured precisely - but it needs a uniform, calibrated capillary.