CHEMVEN

Langmuir Adsorption Isotherm: Acetic Acid on Activated Charcoal

To test the Langmuir adsorption isotherm and find the monolayer capacity a_max and adsorption coefficient b.

Level: UniversitySafety: Needs supervisionTime: 2 h
Aim of Experiment: To test the Langmuir adsorption isotherm and find the monolayer capacity a_max and adsorption coefficient b.

Theoretical Foundations

Langmuir's model assumes monolayer adsorption on equivalent sites: x/m = a_max·b·c/(1 + b·c). Rearranged, c/(x/m) = 1/(a_max·b) + c/a_max, so a plot of c/(x/m) against c is linear with slope 1/a_max and intercept 1/(a_max·b).

Required Apparatus & Chemicals

Laboratory Apparatus

  • Stoppered conical flasks (5)
  • Burette
  • Pipette
  • Balance
  • Filtration set
  • Shaker
  • Measuring cylinders

Chemical Reagents

  • Acetic acid (0.40 M stock)
  • Activated charcoal
  • Sodium hydroxide (0.10 M)
  • Phenolphthalein
  • Distilled water

Step-by-Step Practical Procedure

  1. Prepare 50 mL solutions of 0.40, 0.30, 0.20, 0.10 and 0.05 M acetic acid.
  2. Add 2.00 g charcoal to each; shake 30 min.
  3. Filter, discard first filtrate, titrate 10 mL against 0.10 M NaOH.
  4. Compute c and x/m for each flask.
  5. Plot c/(x/m) vs c; read slope and intercept.
  6. Calculate a_max = 1/slope and b = 1/(a_max x intercept).

Observations & Expected Results

Typical student data (c in M, x/m in g/g): (0.10, 0.050), (0.20, 0.080), (0.30, 0.095), (0.40, 0.107). c/(x/m) = 2.00, 2.50, 3.16, 3.74 - linear in c, confirming Langmuir behaviour at higher concentrations.

Worked Stoichiometric Calculations

Problem: From the data above, the linear plot c/(x/m) vs c has slope 5.8 L/g and intercept 1.42 L^2/(g·mol). Find a_max and b.

Working: a_max = 1/slope = 1/5.8 = 0.172 g of acid per g of charcoal (monolayer capacity). b = 1/(a_max x intercept) = 1/(0.172 x 1.42) = 1/0.244 = 4.1 L/mol. The large b indicates strong adsorption affinity.

Safety Precautions & Hazard Control

  • Allow full equilibration; Langmuir assumes dynamic equilibrium.
  • Work at constant temperature (b is temperature-dependent).
  • Use the same charcoal batch for all flasks.
  • Avoid charcoal fines passing the filter.

Waste Disposal Protocol

Neutralise filtrates before drain disposal; spent charcoal to solid waste.

Viva Voce Oral Defense Questions & Answers

Q: What are Langmuir's three assumptions?

A: Monolayer coverage, energetically equivalent sites, no lateral interaction between adsorbed molecules.

Q: How does Langmuir differ from Freundlich?

A: Langmuir saturates at a monolayer (a_max); Freundlich has no saturation limit and is empirical.

Q: What does a large b mean?

A: Strong adsorbate-adsorbent affinity; the isotherm rises steeply at low c.

← Back to Experiments Directory