CHEMVEN

Photochemical Fading: Sunlight Bleaching of Methylene Blue

Follow the photochemical bleaching of methylene blue in sunlight and test for first-order decay.

Level: UniversitySafety: SafeTime: 2 h
Aim of Experiment: Follow the photochemical bleaching of methylene blue in sunlight and test for first-order decay.

Theoretical Foundations

Light absorption promotes the dye to an excited state that reacts (e.g. with dissolved oxygen or a donor), bleaching the colour. With constant light intensity, the rate is proportional to [dye]: first-order fading, ln(A0/A) = kt, where k depends on light intensity.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Colorimeter (660 nm)
  • Cuvettes or clear bottles
  • Stopwatch
  • Sunny windowsill or lamp
  • Aluminium foil (dark control)

Chemical Reagents

  • Methylene blue, 0.0010% solution
  • Distilled water
  • Aluminium foil (for the dark control)

Step-by-Step Practical Procedure

  1. Fill two clear bottles with dye solution; wrap one in foil (dark control).
  2. Place both in bright sunlight; start timing.
  3. Measure absorbance every 15 min for 2 h.
  4. Plot ln(A0/A) versus t for the exposed sample.
  5. Compare with the dark control.

Observations & Expected Results

Typical student data: exposed sample fades steadily (first-order plot linear, k ~ 0.005 min^-1 in bright sun); the foil-wrapped control barely changes.

Worked Stoichiometric Calculations

Problem: Typical student data: A0 = 0.90, A = 0.45 at t = 140 min (sunlit). Calculate k and t1/2.

Working: k = (1/140) ln(0.90/0.45) = 0.693/140 = 4.95 x 10^-3 min^-1. t1/2 = 0.693/k = 140 min.

Safety Precautions & Hazard Control

  • Keep the light intensity as constant as possible; note cloud cover.
  • Keep temperature similar for both bottles.
  • Do not look directly at intense lamps.

Waste Disposal Protocol

Dilute dye to the sink with water.

Viva Voce Oral Defense Questions & Answers

Q: Why the dark control?

A: To prove the fading is photochemical, not thermal or oxidative in the dark.

Q: What is the quantum yield?

A: Molecules reacted per photon absorbed; it measures photochemical efficiency.

Q: Why first order?

A: At constant light intensity, the excitation rate is proportional to the number of dye molecules.

← Back to Experiments Directory