CHEMVEN

Fenton Reaction Kinetics: Iron(II) and Hydrogen Peroxide

Follow the kinetics of the Fenton reaction by the fading of an indicator dye oxidised by hydroxyl radicals.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: Follow the kinetics of the Fenton reaction by the fading of an indicator dye oxidised by hydroxyl radicals.

Theoretical Foundations

Fe2+ + H2O2 -> Fe3+ + OH- + OH radical. The hydroxyl radical rapidly bleaches methylene blue. With [Fe2+] and [H2O2] in excess over the dye, the dye-fading time measures the radical generation rate; varying [Fe2+] gives its order.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes
  • Pipettes
  • Stopwatch
  • White background
  • Water bath at 25 C

Chemical Reagents

  • Iron(II) sulfate, 0.010-0.050 M (fresh, acidified)
  • Hydrogen peroxide, 0.10 M
  • Methylene blue, 0.0010% solution
  • Sulfuric acid, 0.10 M

Step-by-Step Practical Procedure

  1. Prepare tubes with fixed H2O2, acid and dye volumes at 25 C.
  2. Add FeSO4 solutions of different concentrations, start timing, and mix.
  3. Record the time for the blue colour to vanish.
  4. Compute 1/t for each run.
  5. Plot log(1/t) versus log[Fe2+] and read the order.

Observations & Expected Results

Typical student data: fading times of 180, 90, 60, 45 s as [Fe2+] rises stepwise; log-log slope 1.0 (first order in Fe2+, illustrative).

Worked Stoichiometric Calculations

Problem: Typical student data: t = 180 s at [Fe2+] = 0.010 M and t = 45 s at 0.040 M. Find the order in Fe2+.

Working: Rate ratio = 180/45 = 4.0; concentration ratio = 4.0. 4.0^n = 4.0 gives n = 1: first order in Fe2+.

Safety Precautions & Hazard Control

  • FeSO4 solutions air-oxidise; prepare fresh and keep acidified.
  • H2O2 irritates skin; wear gloves.
  • Work at constant pH; the Fenton rate is pH sensitive.

Waste Disposal Protocol

Iron-containing solutions to the sink well diluted (small scale).

Viva Voce Oral Defense Questions & Answers

Q: What is the Fenton reaction used for?

A: Generating hydroxyl radicals for oxidising organic pollutants in wastewater treatment.

Q: Why must the solution be acidic?

A: Fe2+ precipitates as hydroxide at higher pH, and the radical yield is optimal near pH 3.

Q: Is the dye part of the rate law?

A: No: it is a probe consumed after the rate-determining radical generation; it must be kept at trace levels.