CHEMVEN

Cobalt Complex Aquation at Two Temperatures: Activation Parameters

Determine the activation energy for the aquation of [CoCl(NH3)5]2+ from rate constants at two temperatures.

Level: UniversitySafety: Needs supervisionTime: 2 h
Aim of Experiment: Determine the activation energy for the aquation of [CoCl(NH3)5]2+ from rate constants at two temperatures.

Theoretical Foundations

Measuring k spectrophotometrically at 25 C and 35 C and applying ln(k2/k1) = -(Ea/R)(1/T2 - 1/T1) gives Ea. Ligand substitution at Co(III) typically has Ea near 90-110 kJ/mol; student values are illustrative.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Spectrophotometer
  • Thermostats at 25 C and 35 C
  • Cuvettes
  • Stopwatch

Chemical Reagents

  • [CoCl(NH3)5]Cl2
  • Nitric acid, 0.10 M
  • Distilled water

Step-by-Step Practical Procedure

  1. Determine k at 25.0 C as in the previous experiment.
  2. Repeat at 35.0 C with identical solutions.
  3. Convert to kelvin and apply the two-point Arrhenius equation.
  4. Report Ea.
  5. Discuss whether the value fits a dissociative mechanism.

Observations & Expected Results

Typical student data: k1 = 8.6 x 10^-4 s^-1 at 298 K, k2 = 2.7 x 10^-3 s^-1 at 308 K, giving Ea ~ 92 kJ/mol (illustrative).

Worked Stoichiometric Calculations

Problem: Typical student data: k1 = 8.6 x 10^-4 s^-1 at 298 K, k2 = 2.7 x 10^-3 s^-1 at 308 K. Calculate Ea.

Working: ln(k2/k1) = ln(3.14) = 1.144. 1/308 - 1/298 = -1.09 x 10^-4 K^-1. Ea = 1.144 x 8.314/1.09 x 10^-4 = 8.73 x 10^4 J/mol, about 87 kJ/mol.

Safety Precautions & Hazard Control

  • Equilibrate the cuvette and solutions at each temperature.
  • Cobalt waste to the heavy-metal bottle.
  • Use the same complex batch.

Waste Disposal Protocol

Collect all cobalt solutions as heavy-metal waste.

Viva Voce Oral Defense Questions & Answers

Q: What does a large positive entropy of activation suggest?

A: A dissociative mechanism: breaking the Co-Cl bond increases disorder in the transition state.

Q: How would you get DeltaS*?

A: From the Eyring plot of ln(k/T) versus 1/T.

Q: Why is Co(III) substitution slow?

A: Low-spin d6 has high crystal-field stabilisation; breaking it costs energy, making Co(III) kinetically inert.

← Back to Experiments Directory