CHEMVEN

Amylase: Effect of Substrate Concentration

Show Michaelis-Menten saturation for amylase acting on starch at different substrate concentrations.

Level: UniversitySafety: SafeTime: 60 min
Aim of Experiment: Show Michaelis-Menten saturation for amylase acting on starch at different substrate concentrations.

Theoretical Foundations

At fixed [amylase], the initial digestion rate follows v0 = Vmax[S]/(Km + [S]). Low starch gives first-order behaviour; high starch saturates the enzyme. The time to a fixed colour end point is inversely related to v0.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes
  • Pipettes
  • Stopwatch
  • Water bath at 37 C
  • White tile

Chemical Reagents

  • Starch solutions, 0.25%, 0.5%, 1.0%, 2.0%
  • Amylase solution
  • Buffer pH 6.8
  • Iodine solution

Step-by-Step Practical Procedure

  1. Warm the four starch concentrations with buffer to 37 C.
  2. Add fixed amylase to each and start timing.
  3. Spot onto iodine every 30 s; record the time for the blue colour to disappear.
  4. Plot 1/(achromic time) versus [starch].
  5. Identify the linear (first-order) region and the plateau.

Observations & Expected Results

Typical student data: 1/t rises steeply then levels off: 0.0017, 0.0028, 0.0036, 0.0040 s^-1 at the four starch levels; saturation evident at 2%.

Worked Stoichiometric Calculations

Problem: Typical student data: 1/t = 0.0017 s^-1 at 0.25% starch and 0.0036 s^-1 at 1.0% starch. What kinetic regime is this?

Working: The rate is still rising with [S], so the enzyme is not yet saturated: approximately first-order in substrate here (v ~ (Vmax/Km)[S]).

Safety Precautions & Hazard Control

  • Prepare starch concentrations accurately by dilution.
  • Keep enzyme volume and temperature identical.
  • Use fresh starch solution.

Waste Disposal Protocol

Starch/iodine mixtures to the sink.

Viva Voce Oral Defense Questions & Answers

Q: Why use 1/t as a rate proxy?

A: The same amount of starch must be digested to reach the end point, so rate is proportional to 1/t.

Q: What is the limitation of this proxy?

A: It is an average rate, not a true initial rate; it still shows the saturation trend.

Q: How would you get Km properly?

A: Measure true initial rates (e.g. by reducing-sugar assay) and fit the Michaelis-Menten equation.

← Back to Experiments Directory