CHEMVEN

Amylase on Starch: Temperature Optimum

Find the temperature optimum of salivary or fungal amylase acting on starch.

Level: UniversitySafety: SafeTime: 75 min
Aim of Experiment: Find the temperature optimum of salivary or fungal amylase acting on starch.

Theoretical Foundations

Enzyme rate rises with temperature (Arrhenius) but falls past the optimum as thermal denaturation destroys the active site. The observed rate versus temperature curve is bell-shaped; human amylase optima are near 37 C.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes
  • Water baths at 20-70 C
  • Stopwatch
  • Pipettes
  • White tile
  • Thermometer

Chemical Reagents

  • Starch solution, 1% (fresh)
  • Amylase solution (salivary or fungal)
  • Iodine solution, 0.010 M in KI
  • Phosphate buffer pH 6.8

Step-by-Step Practical Procedure

  1. Prepare starch-buffer mixtures in tubes at 20, 30, 37, 50, 60 and 70 C.
  2. Add a fixed volume of amylase to each, start timing, and mix.
  3. At 1 min intervals spot a drop onto iodine on the tile; the blue-black starch colour fades as starch is digested.
  4. Record the time for the iodine test to stop giving a blue colour at each temperature.
  5. Plot 1/(time) versus temperature and locate the optimum.

Observations & Expected Results

Typical student data: digestion times of 600, 240, 120, 150, 400 s and no digestion at 70 C within 10 min; optimum near 37 C.

Worked Stoichiometric Calculations

Problem: Typical student data: time to achromic point 240 s at 30 C and 120 s at 37 C. By what factor does the rate increase?

Working: Rate ~ 1/t: 240/120 = 2.0 times faster at 37 C than at 30 C.

Safety Precautions & Hazard Control

  • If using saliva, follow institutional biosafety rules; commercial fungal amylase is preferable.
  • Keep pH constant with buffer; amylase is pH sensitive.
  • Do not overheat the starch solution when preparing it.

Waste Disposal Protocol

Starch/iodine mixtures to the sink with water.

Viva Voce Oral Defense Questions & Answers

Q: Why does the rate fall above the optimum?

A: Thermal denaturation: increased molecular motion breaks the weak bonds holding the active site's shape.

Q: Why is the optimum near 37 C for salivary amylase?

A: It evolved to work at human body temperature.

Q: Is the optimum a fixed constant?

A: No: it depends on pH, substrate concentration and the assay time used.