Crystal Violet Kinetics: Rate Constant Units and Consistency Check
Use crystal violet fading data to practise unit analysis of rate constants and check internal consistency of k.
Theoretical Foundations
For rate = k[CV][OH-], k has units L/mol/s. Computing k = k'/[OH-] at several hydroxide concentrations should give the same value; scatter reveals experimental error. This data-analysis exercise reinforces dimensional checking of rate laws.
Required Apparatus & Chemicals
Laboratory Apparatus
- Colorimeter data set (provided)
- Graph paper or spreadsheet
- Scientific calculator
- Ruler
Chemical Reagents
- No wet chemicals handled (data-analysis exercise)
- Supplied printed data set
- Spreadsheet or graph paper
Step-by-Step Practical Procedure
- Take the class k' values at [OH-] = 0.050, 0.10, 0.20 M from the previous experiments.
- Compute k = k'/[OH-] for each.
- Compare the three k values and compute the mean and spread.
- Check the units at each step.
- Discuss which measurement dominates the error.
Observations & Expected Results
Typical student data: k = 0.0230, 0.0231, 0.0231 L/mol/s; excellent consistency, confirming the rate law.
Worked Stoichiometric Calculations
Problem: Typical student data: k' = 2.31 x 10^-3 s^-1 at [OH-] = 0.10 M. Calculate k with units.
Working: k = k'/[OH-] = 2.31 x 10^-3/0.10 = 0.0231 (s^-1)/(mol/L) = 0.0231 L/mol/s.
Safety Precautions & Hazard Control
- Use consistent units (mol/L and seconds) throughout.
- Keep the same temperature for all data sets being compared.
- Quote k with its units always.
Waste Disposal Protocol
No chemical waste if run as a data exercise.
Viva Voce Oral Defense Questions & Answers
Q: Why must k carry units?
A: The rate (M/s) equals k times concentrations; the units of k balance the equation and diagnose the overall order.
Q: What are the units for first, second and third order k?
A: s^-1; L/mol/s; L^2/mol^2/s.
Q: What does consistent k prove?
A: That the assumed rate law correctly describes all the data sets.