CHEMVEN

Persulfate-Iodide Reaction at Three Temperatures: Arrhenius Activation Energy

Determine the activation energy of the persulfate-iodide reaction from clock measurements at three temperatures.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: Determine the activation energy of the persulfate-iodide reaction from clock measurements at three temperatures.

Theoretical Foundations

The initial rate from the clock is proportional to k, so ln(1/t) versus 1/T is linear with slope -Ea/R. Three temperatures allow a proper Arrhenius plot rather than a two-point estimate.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conical flasks
  • Water baths at 20, 30, 40 C
  • Thermometer
  • Stopwatch
  • Pipettes

Chemical Reagents

  • Potassium peroxodisulfate, 0.10 M
  • Potassium iodide, 0.20 M
  • Sodium thiosulfate, 0.010 M
  • Starch solution

Step-by-Step Practical Procedure

  1. Prepare identical clock mixtures and measure the end-point time at 20, 30 and 40 C.
  2. Record the exact temperature of each mixture.
  3. Compute ln(1/t) and 1/T for each.
  4. Plot ln(1/t) versus 1/T and find the slope.
  5. Calculate Ea = -slope x R.

Observations & Expected Results

Typical student data: t = 240, 120, 62 s at 20, 30, 40 C; Arrhenius slope about -6200 K, giving Ea ~ 52 kJ/mol (illustrative).

Worked Stoichiometric Calculations

Problem: Typical student data: t = 240 s at 293 K and t = 62 s at 313 K. Estimate Ea with the two-point equation.

Working: ln(k2/k1) = ln(240/62) = 1.354. 1/313 - 1/293 = -2.18 x 10^-4 K^-1. Ea = 1.354 x 8.314/2.18 x 10^-4 = 5.17 x 10^4 J/mol, about 52 kJ/mol.

Safety Precautions & Hazard Control

  • Pre-equilibrate all solutions at each bath temperature.
  • Measure temperature to 0.1 C.
  • Keep concentrations identical across temperatures.

Waste Disposal Protocol

Quench with thiosulfate; sink disposal with water.

Viva Voce Oral Defense Questions & Answers

Q: Why are three temperatures better than two?

A: A third point checks that the Arrhenius plot is genuinely linear and reveals outliers.

Q: What does Ea ~ 52 kJ/mol tell you?

A: A moderate barrier: the reaction is slow at room temperature but convenient to follow, and it roughly doubles every 10 C.

Q: Does the clock thiosulfate affect Ea?

A: No: it only sets the end point; the rate-determining persulfate-iodide step controls the temperature dependence.

← Back to Experiments Directory