CHEMVEN

Saponification of Ethyl Acetate: Conductometric Rate Constant

Determine the second-order rate constant for the saponification of ethyl acetate by following the conductivity of the reaction mixture.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: Determine the second-order rate constant for the saponification of ethyl acetate by following the conductivity of the reaction mixture.

Theoretical Foundations

CH3COOC2H5 + OH- -> CH3COO- + C2H5OH. Highly mobile OH- ions are replaced by slower acetate ions, so conductivity falls. With equal initial concentrations a, k = (1/at)[x/(a-x)], where x/(a-x) is obtained from conductivities: (C0 - Ct)/(Ct - Cinf).

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conductivity meter with dip cell
  • Beakers
  • Pipettes
  • Stopwatch
  • Thermostat at 25 C
  • Stirrer

Chemical Reagents

  • Ethyl acetate, 0.050 M aqueous
  • Sodium hydroxide, 0.050 M
  • Distilled water (conductivity grade)

Step-by-Step Practical Procedure

  1. Thermostat equal volumes of 0.050 M ester and 0.050 M NaOH at 25 C.
  2. Mix, start the stopwatch, and record conductivity every minute for 40 min.
  3. Measure Cinf on a completed mixture (or after 24 h).
  4. Compute x/(a-x) = (C0 - Ct)/(Ct - Cinf) for each t.
  5. Plot (x/(a-x)) versus t; slope = a·k, so k = slope/a.

Observations & Expected Results

Typical student data: conductivity falls from ~4.2 to ~1.6 mS/cm; the second-order plot is linear with slope 0.0011 min^-1, giving k ~ 0.022 L/mol/min (illustrative).

Worked Stoichiometric Calculations

Problem: Typical student data: a = 0.050 M; at t = 20 min, C0 = 4.20, Ct = 2.90, Cinf = 1.60 mS/cm. Estimate k.

Working: x/(a-x) = (4.20-2.90)/(2.90-1.60) = 1.30/1.30 = 1.00. k = (1/(a x t)) x (x/(a-x)) = (1/(0.050 x 20)) x 1.00 = 1.0 L/mol/min. (Illustrative student data are accelerated; real values are near 0.1 L/mol/min.)

Safety Precautions & Hazard Control

  • Use freshly prepared conductivity water; CO2 absorption changes readings.
  • Keep the cell fully immersed and unstirred during each reading.
  • Maintain 25.0 C; conductivity is temperature sensitive.
  • Rinse the cell between the Cinf measurement and the run.

Waste Disposal Protocol

The dilute acetate/ethanol mixture can go to the sink with water.

Viva Voce Oral Defense Questions & Answers

Q: Why does conductivity fall?

A: Fast hydroxide ions are consumed and replaced by slower, larger acetate ions.

Q: What are the units of a second-order k?

A: L/mol/time (e.g. L mol^-1 min^-1); the units diagnose the order.

Q: Why use equal concentrations?

A: It simplifies the integrated law to x/[a(a-x)] = kt.

← Back to Experiments Directory