CHEMVEN

Capstone: Designing a 1.5 V Galvanic Cell from the Electrochemical Series

To design, build and test a galvanic cell with a target EMF of 1.5 V.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: To design, build and test a galvanic cell with a target EMF of 1.5 V.

Theoretical Foundations

The design uses Edegcell = Edeg(cathode) - Edeg(anode) ~ 1.5 V. The Ag-Zn pair gives 1.56 V; fine-tuning with the Nernst equation (e.g. lowering [Ag+]) trims it to 1.50 V. This reverses the usual workflow: from target voltage to chemistry.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Zn strip
  • Silver wire
  • Beakers
  • Salt bridge
  • Digital voltmeter
  • Volumetric glassware

Chemical Reagents

  • ZnSO4 (1.0 M)
  • AgNO3 (dilute, calculated concentration)
  • KNO3 (salt bridge)

Step-by-Step Practical Procedure

  1. Choose the Ag-Zn pair (Edeg = 1.56 V) and compute the [Ag+] needed for exactly 1.50 V with [Zn2+] = 1.0 M.
  2. Prepare that AgNO3 concentration.
  3. Build the cell and measure the EMF.
  4. Compare with the 1.50 V target.
  5. Discuss error sources and iterate if time permits.

Observations & Expected Results

Cells typically land within 1.47-1.53 V of the 1.50 V target.

Worked Stoichiometric Calculations

Problem: What [Ag+] gives E = 1.50 V for Zn + 2Ag+ -> Zn2+ + 2Ag with [Zn2+] = 1.0 M? (Edeg = 1.56 V)

Working: 1.50 = 1.56 - (0.0591/2) log(1.0/[Ag+]^2). So 0.06 = 0.02955 x (-2 log[Ag+]) = -0.0591 log[Ag+]. log[Ag+] = -0.06/0.0591 = -1.015. [Ag+] = 10^-1.015 = 0.0966 M, about 0.097 M.

Safety Precautions & Hazard Control

  • AgNO3 stains; wear gloves.
  • Prepare the dilute AgNO3 accurately.
  • Switch off the power supply before changing any connections.

Waste Disposal Protocol

Silver waste to recovery; zinc solution to heavy-metal waste.

Viva Voce Oral Defense Questions & Answers

Q: Why was the Ag-Zn pair chosen?

A: Its 1.56 V standard EMF is the closest common pair above 1.5 V, trimmable downward via the Nernst equation.

Q: Could you reach 1.50 V with a Daniell cell instead?

A: No - its maximum standard EMF is 1.10 V, and concentration changes can only shift it by tens of millivolts, never to 1.5 V.