Throwing Power of an Electroplating Bath (Haring-Blum Cell)
To measure the throwing power of a copper plating bath with the Haring-Blum cell.
Theoretical Foundations
Throwing power = (K - M)/(K + M - 2) x 100%, where K is the distance ratio of the two cathodes from the anode and M is the mass ratio of their deposits. Good throwing power (uniform deposits in recesses) comes from high cathode polarisation and conductivity.
Required Apparatus & Chemicals
Laboratory Apparatus
- Haring-Blum cell (long box)
- Copper anode (centre)
- Two copper cathodes at 1:5 distances
- DC supply
- Ammeter
- Balance
Chemical Reagents
- Acid copper sulphate bath
- Distilled water (for rinsing)
- Dilute H2SO4 (bath make-up acid)
Step-by-Step Practical Procedure
- Weigh both cathodes.
- Place them at distances in ratio 1:5 from the central anode.
- Plate at constant current for 30 minutes.
- Re-weigh each cathode.
- Compute M, then the throwing power.
Observations & Expected Results
Typical M ~ 2.5-3.5 for K = 5, giving throwing power ~20-40%.
Worked Stoichiometric Calculations
Problem: K = 5 and the deposit mass ratio M = 3.0. Calculate the throwing power.
Working: TP = (K - M)/(K + M - 2) x 100 = (5 - 3)/(5 + 3 - 2) x 100 = 2/6 x 100 = 33.3%.
Safety Precautions & Hazard Control
- Keep the current constant.
- Position the electrodes accurately.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Bath to electroplating waste.
Viva Voce Oral Defense Questions & Answers
Q: What does high throwing power mean in practice?
A: The bath plates recesses and distant areas almost as thickly as prominent areas - essential for complex shapes.
Q: How can throwing power be improved?
A: By raising bath conductivity, adding levelling agents, or using complexed metal ions that increase cathode polarisation.