Standard Potential of the AgCl/Ag Electrode from a Cell EMF
To determine Edeg(AgCl/Ag) from the EMF of Pt|H2|HCl|AgCl|Ag.
Theoretical Foundations
Cell: Pt|H2(1 atm)|H+(1 M)||Cl-(1 M)|AgCl|Ag. The left electrode is the SHE (0.00 V), so Edegcell = Edeg(AgCl/Ag) - 0 = Edeg(AgCl/Ag). The measured 0.222 V directly gives the standard potential of the silver-silver chloride electrode.
Required Apparatus & Chemicals
Laboratory Apparatus
- Platinised Pt electrode
- AgCl-coated Ag wire
- H2 supply
- Beaker
- Salt bridge
- Digital voltmeter
Chemical Reagents
- Hydrochloric acid (1.0 M)
- Hydrogen gas
- Distilled water (for rinsing glassware and electrodes)
Step-by-Step Practical Procedure
- Set up the hydrogen electrode in 1.0 M HCl with H2 at 1 atm.
- Prepare the AgCl|Ag electrode in the same acid.
- Join via a salt bridge and measure Ecell.
- Identify the measured value with Edeg(AgCl/Ag).
- Compare with 0.222 V.
Observations & Expected Results
Steady reading ~0.22 V (AgCl side positive).
Worked Stoichiometric Calculations
Problem: Ecell = 0.222 V for Pt|H2(1 atm)|H+(1 M)||Cl-(1 M)|AgCl|Ag. Deduce Edeg(AgCl/Ag).
Working: Edegcell = Edeg(right) - Edeg(left) = Edeg(AgCl/Ag) - 0.00 = 0.222 V. Hence Edeg(AgCl/Ag) = +0.222 V.
Safety Precautions & Hazard Control
- H2 is flammable; no flames, ventilate well.
- HCl is corrosive; wear gloves.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Neutralise the acid before drain disposal.
Viva Voce Oral Defense Questions & Answers
Q: Why can the measured EMF be read directly as the electrode potential?
A: Because the other electrode is the SHE, defined as exactly 0.00 V.
Q: Why use HCl as the common electrolyte?
A: It supplies both H+ for the hydrogen electrode and Cl- for the AgCl electrode at unit activity.