Electrogravimetric Determination of Copper in Brass
To determine the percentage of copper in brass by electrogravimetry.
Theoretical Foundations
Brass is dissolved in HNO3, and Cu2+ is selectively deposited on a weighed Pt cathode at controlled potential: Cu2+ + 2e- -> Cu. Zn2+ stays in solution (Edeg = -0.76 V). The cathode mass gain gives %Cu directly - a classic quantitative electroanalytical method.
Required Apparatus & Chemicals
Laboratory Apparatus
- Platinum gauze cathode
- Pt anode
- DC supply
- Ammeter
- Analytical balance
- Beaker
Chemical Reagents
- Brass sample (~0.5 g)
- Concentrated nitric acid
- Sulphuric acid
- Distilled water
Step-by-Step Practical Procedure
- Weigh ~0.5 g of brass accurately.
- Dissolve in minimum concentrated HNO3, then fume off nitrogen oxides with H2SO4.
- Dilute, insert weighed Pt gauze cathode and electrolyse at ~2 A until the blue colour disappears.
- Wash, dry and re-weigh the cathode.
- Calculate %Cu in the brass.
Observations & Expected Results
Blue colour fades completely; cathode gains a bright copper coat; typical result 60-70% Cu.
Worked Stoichiometric Calculations
Problem: 0.5000 g of brass gives a cathode gain of 0.3250 g. Find %Cu.
Working: %Cu = 0.3250/0.5000 x 100 = 65.0%.
Safety Precautions & Hazard Control
- Concentrated HNO3: use a fume hood, gloves and eye protection.
- Ensure complete deposition (test a drop with ammonia - no blue).
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Acidic zinc-containing liquor to heavy-metal waste after neutralisation.
Viva Voce Oral Defense Questions & Answers
Q: Why doesn't zinc deposit with the copper?
A: Zn2+/Zn is at -0.76 V, far more negative; at the controlled cathode potential only Cu2+ reduces.
Q: Why is a Pt gauze cathode used?
A: Large surface area gives fast, complete deposition, and Pt is inert and weighable.