CHEMVEN

Electrogravimetric Determination of Copper in Brass

To determine the percentage of copper in brass by electrogravimetry.

Level: UniversitySafety: Advanced lab onlyTime: 2 h
Aim of Experiment: To determine the percentage of copper in brass by electrogravimetry.

Theoretical Foundations

Brass is dissolved in HNO3, and Cu2+ is selectively deposited on a weighed Pt cathode at controlled potential: Cu2+ + 2e- -> Cu. Zn2+ stays in solution (Edeg = -0.76 V). The cathode mass gain gives %Cu directly - a classic quantitative electroanalytical method.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Platinum gauze cathode
  • Pt anode
  • DC supply
  • Ammeter
  • Analytical balance
  • Beaker

Chemical Reagents

  • Brass sample (~0.5 g)
  • Concentrated nitric acid
  • Sulphuric acid
  • Distilled water

Step-by-Step Practical Procedure

  1. Weigh ~0.5 g of brass accurately.
  2. Dissolve in minimum concentrated HNO3, then fume off nitrogen oxides with H2SO4.
  3. Dilute, insert weighed Pt gauze cathode and electrolyse at ~2 A until the blue colour disappears.
  4. Wash, dry and re-weigh the cathode.
  5. Calculate %Cu in the brass.

Observations & Expected Results

Blue colour fades completely; cathode gains a bright copper coat; typical result 60-70% Cu.

Worked Stoichiometric Calculations

Problem: 0.5000 g of brass gives a cathode gain of 0.3250 g. Find %Cu.

Working: %Cu = 0.3250/0.5000 x 100 = 65.0%.

Safety Precautions & Hazard Control

  • Concentrated HNO3: use a fume hood, gloves and eye protection.
  • Ensure complete deposition (test a drop with ammonia - no blue).
  • Switch off the power supply before changing any connections.

Waste Disposal Protocol

Acidic zinc-containing liquor to heavy-metal waste after neutralisation.

Viva Voce Oral Defense Questions & Answers

Q: Why doesn't zinc deposit with the copper?

A: Zn2+/Zn is at -0.76 V, far more negative; at the controlled cathode potential only Cu2+ reduces.

Q: Why is a Pt gauze cathode used?

A: Large surface area gives fast, complete deposition, and Pt is inert and weighable.

← Back to Experiments Directory