Lead-Acid Accumulator: Charging and Discharging
To cycle a small lead-acid cell and track voltage and acid density.
Theoretical Foundations
Discharge: Pb + PbO2 + 2H2SO4 -> 2PbSO4 + 2H2O, Edeg = 1.69 - (-0.36) = 2.05 V. Charging reverses it. Because H2SO4 is consumed on discharge, the acid density falls - the basis of the hydrometer state-of-charge test.
Required Apparatus & Chemicals
Laboratory Apparatus
- Lead plates (one pasted with PbO2)
- Beaker
- DC supply with current limit
- Voltmeter
- Ammeter
- Hydrometer or density measurement
Chemical Reagents
- Sulphuric acid (2 M, battery acid strength for the model)
- Distilled water (for topping up)
- Sodium bicarbonate solution (for neutralising spills)
Step-by-Step Practical Procedure
- Assemble Pb|H2SO4|PbO2 and record the open-circuit voltage (~2.0 V).
- Discharge through a small bulb; record voltage vs time.
- Measure the acid density before and after discharge.
- Recharge at constant current, watching the voltage rise to ~2.4 V.
- Confirm the density recovers.
Observations & Expected Results
Discharge plateau ~2.0 V falling at the end; density drops measurably; recharge restores both.
Worked Stoichiometric Calculations
Problem: Calculate Edegcell from Edeg(PbO2/PbSO4) = +1.69 V and Edeg(PbSO4/Pb) = -0.36 V.
Working: Edegcell = 1.69 - (-0.36) = 2.05 V.
Safety Precautions & Hazard Control
- H2SO4 is corrosive; wear gloves and eye protection.
- Charging evolves H2 and O2 - ventilate, no sparks.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Lead plates and acid are hazardous waste; never pour down the drain.
Viva Voce Oral Defense Questions & Answers
Q: Why does the acid density indicate the state of charge?
A: Discharge consumes H2SO4 and produces water (see the cell reaction), so density falls in direct proportion to charge withdrawn.
Q: Why must a lead-acid battery never be left discharged?
A: PbSO4 recrystallises into large inactive crystals (sulphation), permanently reducing capacity.