CHEMVEN

Potentiometric Titration of a Halide Mixture (I- and Cl-)

To determine iodide and chloride in a mixture by successive potentiometric endpoints.

Level: UniversitySafety: Needs supervisionTime: 75 min
Aim of Experiment: To determine iodide and chloride in a mixture by successive potentiometric endpoints.

Theoretical Foundations

AgI (Ksp ~ 8 x 10^-17) precipitates long before AgCl (Ksp ~ 1.8 x 10^-10). Titrating with Ag+ gives two potential jumps: the first when I- is consumed, the second when Cl- is consumed. V1 gives I-; V2 - V1 gives Cl-.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Silver indicator electrode
  • Calomel reference
  • Digital voltmeter
  • Burette
  • Beaker
  • Stirrer

Chemical Reagents

  • Mixture of KI and NaCl (unknown)
  • Silver nitrate (0.050 M standard)
  • Distilled water (for rinsing glassware and electrodes)

Step-by-Step Practical Procedure

  1. Pipette 25.0 mL of the mixture.
  2. Titrate with AgNO3, recording E in small steps.
  3. Plot E and DeltaE/DeltaV vs V.
  4. Identify the two jumps (V1, V2).
  5. Calculate [I-] from V1 and [Cl-] from V2 - V1.

Observations & Expected Results

Two distinct jumps: first ~100 mV (I- endpoint), second ~150 mV (Cl- endpoint).

Worked Stoichiometric Calculations

Problem: V1 = 10.2 mL and V2 = 30.6 mL of 0.0500 M AgNO3 for 25.0 mL of mixture. Find [I-] and [Cl-].

Working: [I-] = 0.0500 x 0.0102/0.0250 = 0.0204 M. [Cl-] = 0.0500 x (0.0306 - 0.0102)/0.0250 = 0.0500 x 0.0204/0.0250 = 0.0408 M.

Safety Precautions & Hazard Control

  • Protect from light (AgI darkens).
  • Stir well near endpoints; precipitates adsorb ions.
  • Switch off the power supply before changing any connections.

Waste Disposal Protocol

Collect silver halide waste for recovery.

Viva Voce Oral Defense Questions & Answers

Q: Why does iodide precipitate first?

A: AgI has a far smaller Ksp, so [Ag+] needed to start precipitation is ~10^-8 M for I- versus ~10^-5 M for Cl-.

Q: Would this work for a Cl-/Br- mixture?

A: Yes, but the jumps are closer (Ksp values nearer); slower titration and careful derivative analysis are needed.

← Back to Experiments Directory