CHEMVEN

Solubility Product of AgCl by EMF Measurement

To determine Ksp of silver chloride from the EMF of a suitable cell.

Level: UniversitySafety: Needs supervisionTime: 75 min
Aim of Experiment: To determine Ksp of silver chloride from the EMF of a suitable cell.

Theoretical Foundations

Cell: Ag|Ag+(1 M)||Cl-(1 M)|AgCl|Ag. Edegcell = Edeg(AgCl/Ag) - Edeg(Ag+/Ag) = 0.222 - 0.799 = -0.577 V. For AgCl(s) <=> Ag+ + Cl- (n = 1), log Ksp = nEdeg/0.0591 = -0.577/0.0591, giving Ksp ~ 1.7 x 10^-10.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Silver wires
  • Beaker with AgCl-coated wire
  • Salt bridge
  • Digital voltmeter

Chemical Reagents

  • AgNO3 (1.0 M)
  • KCl (1.0 M)
  • AgCl (solid)

Step-by-Step Practical Procedure

  1. Prepare an AgCl-coated silver wire (anodise Ag in KCl).
  2. Set up Ag|Ag+(1 M) and AgCl|Ag|Cl-(1 M) half-cells.
  3. Join with a salt bridge and measure Ecell.
  4. Compute Edegcell and hence log Ksp.
  5. Compare with the literature 1.8 x 10^-10.

Observations & Expected Results

Typical Ecell ~ -0.577 V (Ag+ side positive); Ksp calculates to ~1.5-1.8 x 10^-10.

Worked Stoichiometric Calculations

Problem: Edegcell = -0.577 V for the AgCl dissolution cell (n = 1). Calculate Ksp at 25 C.

Working: log Ksp = 1 x (-0.577)/0.0591 = -9.764. Ksp = 10^-9.764 = 1.72 x 10^-10, about 1.7 x 10^-10.

Safety Precautions & Hazard Control

  • AgNO3 stains; wear gloves.
  • Keep AgCl electrodes in the dark.
  • Switch off the power supply before changing any connections.

Waste Disposal Protocol

Collect silver waste for recovery.

Viva Voce Oral Defense Questions & Answers

Q: Why is Edegcell negative here?

A: Dissolution of AgCl is non-spontaneous under standard conditions - consistent with its tiny Ksp.

Q: Why is this method better than direct analysis?

A: The solubility (~10^-5 M) is far too low for titration; EMF measures the equilibrium constant directly.