Determination of pKa of a Weak Acid Potentiometrically
To find the pKa of acetic acid from its potentiometric titration curve.
Theoretical Foundations
For HA <=> H+ + A-, pH = pKa + log([A-]/[HA]) (Henderson-Hasselbalch). At half-neutralisation [A-] = [HA], so pH = pKa. The half-equivalence pH read from the titration curve directly gives pKa.
Required Apparatus & Chemicals
Laboratory Apparatus
- pH meter
- Burette
- Beaker
- Stirrer
- Buffers for calibration
Chemical Reagents
- Acetic acid (0.10 M)
- Sodium hydroxide (0.10 M)
- Distilled water (for rinsing glassware and electrodes)
Step-by-Step Practical Procedure
- Calibrate the pH meter.
- Titrate 25.0 mL of 0.10 M acetic acid with 0.10 M NaOH, recording pH.
- Plot pH vs V; find the endpoint Ve from the derivative.
- Read the pH at Ve/2 - this is pKa.
- Calculate Ka = 10^(-pKa).
Observations & Expected Results
Typical Ve ~ 25.0 mL; pH at half-point ~ 4.76.
Worked Stoichiometric Calculations
Problem: The half-equivalence pH is 4.76. Find pKa and Ka.
Working: pKa = 4.76. Ka = 10^-4.76 = 1.74 x 10^-5, about 1.7 x 10^-5.
Safety Precautions & Hazard Control
- Calibrate carefully; pKa accuracy depends on pH accuracy.
- Stir gently to protect the electrode.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Sodium acetate solution can go down the drain.
Viva Voce Oral Defense Questions & Answers
Q: Why does pH = pKa at half-neutralisation?
A: Half the HA has become A-, so [A-]/[HA] = 1 and log(1) = 0 in the Henderson-Hasselbalch equation.
Q: What is the buffer region of the curve?
A: The flat central portion around pKa, where added base is absorbed with little pH change - the basis of buffer action.