CHEMVEN

Solubility of a Sparingly Soluble Salt by Conductance

To determine the solubility of BaSO4 from the conductivity of its saturated solution.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To determine the solubility of BaSO4 from the conductivity of its saturated solution.

Theoretical Foundations

For a sparingly soluble salt, the saturated solution is so dilute that Lambda_m ~ Lambda_m^0. Solubility s (mol/L) = kappa x 1000/Lambda_m^0, where kappa is the conductivity of the salt alone (solution minus water blank) and Lambda_m^0 = lambda^0(Ba2+) + lambda^0(SO4(2-)).

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conductivity meter
  • Beaker
  • Filter funnel
  • Stirrer

Chemical Reagents

  • Barium sulphate (solid, excess)
  • Conductivity water
  • Distilled water (for rinsing glassware and electrodes)

Step-by-Step Practical Procedure

  1. Shake excess BaSO4 with conductivity water for 15 minutes.
  2. Filter off undissolved solid.
  3. Measure kappa of the filtrate and of the pure water blank.
  4. Compute kappa(BaSO4) = kappa(solution) - kappa(water).
  5. Calculate s = kappa x 1000/Lambda_m^0 (use 287.2 S cm2/mol).

Observations & Expected Results

Typical: kappa(solution) ~ 3.0 x 10^-6, water ~ 1.0 x 10^-6 S/cm, giving s ~ 7 x 10^-6 mol/L.

Worked Stoichiometric Calculations

Problem: kappa(BaSO4) = 2.0 x 10^-6 S/cm and Lambda_m^0 = 287.2 S cm2/mol. Find the solubility in mol/L and g/L (M = 233.4).

Working: s = 2.0 x 10^-6 x 1000/287.2 = 6.96 x 10^-6 mol/L. In g/L: 6.96 x 10^-6 x 233.4 = 1.62 x 10^-3 g/L, about 1.6 mg/L.

Safety Precautions & Hazard Control

  • Barium compounds are toxic; wear gloves.
  • The water blank must be measured; it is comparable to the signal.
  • Wipe up any spills immediately and keep the bench dry.

Waste Disposal Protocol

Collect BaSO4 residues as barium waste.

Viva Voce Oral Defense Questions & Answers

Q: Why is this method ideal for sparingly soluble salts?

A: Titration and gravimetry fail at such low concentrations, but conductivity is sensitive enough and needs no indicator.

Q: Why subtract the water conductivity?

A: Dissolved CO2 makes even pure water conduct; the blank correction isolates the salt's contribution.