Cathodic Protection of Iron with a Magnesium Anode
To demonstrate cathodic protection using a sacrificial magnesium anode.
Theoretical Foundations
Connecting iron to Mg (Edeg = -2.37 V) forces the iron to be the cathode of the galvanic couple (Ecell ~ 1.93 V). Oxidation occurs at the Mg anode, which is consumed instead of the iron - the principle used for pipelines and ship hulls.
Required Apparatus & Chemicals
Laboratory Apparatus
- Iron nail
- Magnesium ribbon
- Beaker
- Connecting wire
- Control nail in a second beaker
Chemical Reagents
- Sodium chloride solution (3.5%)
- Distilled water (for rinsing glassware and electrodes)
- Sodium bicarbonate (for neutralising small spills)
Step-by-Step Practical Procedure
- Wire the Mg ribbon firmly to the iron nail.
- Immerse the couple in salt water; set up a bare control nail separately.
- Observe over 3 days.
- Record H2 bubbles on the Mg and the condition of the iron.
Observations & Expected Results
Control nail rusts; protected nail stays bright while Mg corrodes with H2 evolution.
Worked Stoichiometric Calculations
Problem: If the Mg anode loses 0.20 g (Mg -> Mg2+, M = 24.3), what charge has flowed?
Working: Moles Mg = 0.20/24.3 = 0.00823 mol. Moles e- = 0.01646 mol. Q = 0.01646 x 96485 = 1588 C, about 1.6 x 10^3 C.
Safety Precautions & Hazard Control
- Keep Mg away from flames.
- Ensure the wire contact stays tight.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Salt solution to drain; spent Mg to solid waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is magnesium preferred over zinc for buried pipelines?
A: Its more negative potential drives a larger protective current through high-resistance soil.
Q: What happens when the sacrificial anode is fully consumed?
A: Protection stops and the iron begins to corrode - anodes must be inspected and replaced.