CHEMVEN

Electroplating Copper onto an Iron Nail

To electroplate a uniform copper coating onto an iron nail and calculate its thickness.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To electroplate a uniform copper coating onto an iron nail and calculate its thickness.

Theoretical Foundations

The nail is the cathode in an acidified CuSO4 bath: Cu2+ + 2e- -> Cu. A copper anode replenishes Cu2+. The deposit mass from Faraday's law gives the mean coating thickness t = m/(rho x A) with rho(Cu) = 8.96 g/cm3.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Iron nail (cathode)
  • Copper plate (anode)
  • 250 mL beaker
  • DC supply
  • Ammeter
  • Balance
  • Sandpaper

Chemical Reagents

  • CuSO4 (0.5 M) with 0.5 M H2SO4
  • Distilled water (for rinsing)
  • Laboratory detergent (for degreasing the nail)

Step-by-Step Practical Procedure

  1. Clean the nail with sandpaper, degrease, and weigh it.
  2. Set up the bath with the nail centred opposite the Cu anode.
  3. Plate at ~1.5 A for 20 minutes.
  4. Rinse, dry and re-weigh the nail.
  5. Calculate the Cu mass and estimate the coating thickness.

Observations & Expected Results

Bright adherent pink copper coating; typical mass gain ~0.59 g.

Worked Stoichiometric Calculations

Problem: A nail of surface area 12 cm2 gains 0.592 g of Cu. Estimate the coating thickness (rho = 8.96 g/cm3).

Working: Volume Cu = 0.592/8.96 = 0.0661 cm3. Thickness = V/A = 0.0661/12 = 0.00551 cm = 55 micrometres.

Safety Precautions & Hazard Control

  • Degrease the nail thoroughly or the plate will peel.
  • Acidic bath: wear gloves and eye protection.
  • Switch off the power supply before changing any connections.

Waste Disposal Protocol

Return the plating bath to the electroplating waste bottle.

Viva Voce Oral Defense Questions & Answers

Q: Why must the nail be the cathode?

A: Reduction (Cu2+ -> Cu) occurs at the cathode; making the nail the anode would dissolve it instead.

Q: What causes a dark, powdery deposit?

A: Too high current density: H2 evolves alongside Cu, giving a spongy non-adherent plate - 'burning'.

← Back to Experiments Directory