Predicting the Products of Electrolysis: A Systematic Study
To predict and verify the products of electrolysis for six different electrolytes.
Theoretical Foundations
Product prediction rules: at the cathode, the species with the more positive reduction potential discharges (e.g. Cu2+ before H2O; H2O before Na+). At the anode, the species with the lower oxidation potential discharges, modified by concentration and overvoltage (e.g. concentrated Cl- gives Cl2).
Required Apparatus & Chemicals
Laboratory Apparatus
- Beakers
- Graphite and copper electrodes
- DC supply
- Test tubes
- pH paper
- Splints
Chemical Reagents
- CuSO4 (0.5 M)
- NaCl (concentrated)
- Na2SO4 (0.5 M)
- KI (0.5 M)
- CuSO4 with Cu electrodes
- Dilute H2SO4
Step-by-Step Practical Procedure
- For each electrolyte, predict cathode and anode products using Edeg values and the rules.
- Electrolyse with the specified electrodes at ~0.5 A.
- Test gases and solution changes (pH, colour).
- Tabulate predicted vs observed products.
- Explain any discrepancies (overvoltage, concentration effects).
Observations & Expected Results
Predictions hold: CuSO4/Pt gives Cu + O2; brine gives H2 + Cl2; Na2SO4 gives H2 + O2; KI gives H2 + I2; CuSO4/Cu gives Cu transfer; H2SO4 gives H2 + O2.
Worked Stoichiometric Calculations
Problem: Predict the products of electrolysing concentrated NaCl with graphite electrodes and justify with Edeg values.
Working: Possible cathode: Na+ (-2.71 V) vs H2O (-0.83 V at pH 7 as 2H2O + 2e- -> H2 + 2OH-) - water reduces more easily, so H2. Possible anode: Cl- (+1.36 V) vs H2O (+1.23 V) - O2 is thermodynamically favoured, but high [Cl-] and large O2 overvoltage on graphite make Cl2 the observed product.
Safety Precautions & Hazard Control
- Vent Cl2 in a fume hood.
- Keep electrode pairs and predictions labelled to avoid mix-ups.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Neutralise acidic/alkaline liquors; heavy metals to the labelled bottle.
Viva Voce Oral Defense Questions & Answers
Q: Why does Na+ never discharge from aqueous solution?
A: Its reduction potential (-2.71 V) is far more negative than water reduction, so water is always reduced first.
Q: What is overvoltage and why does it matter here?
A: The extra voltage beyond the reversible value needed to drive gas evolution at a practical rate; it lets Cl2 beat O2 kinetically at the anode.