CHEMVEN

Current Efficiency of a Copper Refining Cell

To determine the current efficiency of copper deposition in a refining-type cell.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To determine the current efficiency of copper deposition in a refining-type cell.

Theoretical Foundations

Current efficiency = (actual mass deposited / theoretical mass) x 100%. Less than 100% efficiency arises from side reactions such as H2 evolution, current leakage, or re-dissolution of the deposit. Industrial refineries aim for >95%.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Copper voltameter
  • DC supply
  • Ammeter
  • Stopwatch
  • Analytical balance
  • Rheostat

Chemical Reagents

  • CuSO4 (0.5 M, acidified)
  • Distilled water (for rinsing the cathode)
  • Acetone (for final drying of the cathode)

Step-by-Step Practical Procedure

  1. Weigh the cathode accurately.
  2. Pass 2.0 A for exactly 20 minutes at constant current.
  3. Wash, dry and re-weigh the cathode.
  4. Calculate the theoretical mass from Faraday's law.
  5. Compute the current efficiency and suggest reasons for any shortfall.

Observations & Expected Results

Typical actual deposit ~0.76 g versus theoretical 0.79 g: efficiency ~96%.

Worked Stoichiometric Calculations

Problem: For 2.0 A passed for 20 min, the cathode gains 0.760 g. Find the current efficiency.

Working: Q = 2.0 x 1200 = 2400 C. Theoretical m = 2400 x 63.5/(2 x 96485) = 152,400/192,970 = 0.790 g. Efficiency = 0.760/0.790 x 100 = 96.2%.

Safety Precautions & Hazard Control

  • Avoid excessive current density that evolves H2.
  • Weigh promptly to avoid oxidation errors.
  • Switch off the power supply before changing any connections.

Waste Disposal Protocol

Return the bath to the electroplating waste bottle.

Viva Voce Oral Defense Questions & Answers

Q: What causes current efficiency below 100%?

A: Side reactions (H2 evolution at the cathode), stray currents, and mechanical loss of deposit during washing.

Q: Why does industry care about current efficiency?

A: It directly fixes the electricity cost per tonne of refined metal.