Verification of Faraday's Second Law: Cu and Ag in Series
To verify that masses deposited by the same charge are proportional to equivalent masses.
Theoretical Foundations
Faraday's second law: with the same Q through cells in series, m1/m2 = E1/E2 where E is the equivalent mass (M/n). For Cu (E = 31.75) and Ag (E = 108), mAg/mCu should equal 108/31.75 = 3.40.
Required Apparatus & Chemicals
Laboratory Apparatus
- Copper voltameter (Cu electrodes in CuSO4)
- Silver voltameter (Ag cathode, Pt or Ag anode in AgNO3)
- DC supply
- Ammeter
- Stopwatch
- Analytical balance
Chemical Reagents
- CuSO4 (0.5 M, acidified)
- AgNO3 (0.5 M)
- Distilled water (for rinsing glassware and electrodes)
Step-by-Step Practical Procedure
- Weigh the Cu cathode and Ag cathode.
- Connect the two voltameters in series with the supply and ammeter.
- Pass ~1.0 A for 30 minutes.
- Wash, dry and re-weigh both cathodes.
- Compute mAg/mCu and compare with 108/31.75.
Observations & Expected Results
Typical: mCu ~ 0.59 g, mAg ~ 2.01 g; ratio ~3.4, matching theory.
Worked Stoichiometric Calculations
Problem: If 0.592 g of Cu is deposited, what mass of Ag is expected in the series cell?
Working: mAg = mCu x (EAg/ECu) = 0.592 x (108/31.75) = 0.592 x 3.402 = 2.014 g, about 2.01 g.
Safety Precautions & Hazard Control
- The same current must pass through both cells - check series wiring.
- AgNO3 stains; wear gloves.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Keep copper and silver baths separate; silver waste goes for recovery.
Viva Voce Oral Defense Questions & Answers
Q: State Faraday's second law.
A: When the same quantity of electricity passes through different electrolytes, the masses deposited are proportional to their chemical equivalent masses.
Q: Why must the cells be in series?
A: So that exactly the same charge Q flows through each voltameter.