Effect of Temperature on Cell EMF
To measure the temperature coefficient (dE/dT) of the Daniell cell EMF.
Theoretical Foundations
EMF varies with temperature: dE/dT = DeltaS/(nF). For the Daniell cell the coefficient is small and negative (about -0.0004 V/K), so warming the cell slightly lowers its EMF.
Required Apparatus & Chemicals
Laboratory Apparatus
- Daniell cell setup
- Digital voltmeter
- Thermostat water bath or beakers of warm/cold water
- Thermometer
Chemical Reagents
- ZnSO4 (1.0 M)
- CuSO4 (1.0 M)
- KNO3 (salt bridge)
Step-by-Step Practical Procedure
- Build the Daniell cell and record E at room temperature.
- Warm both half-cells to ~40 C in a water bath and record E.
- Cool to ~10 C with ice water and record E.
- Plot E versus T and find dE/dT.
- Calculate DeltaS = nF(dE/dT).
Observations & Expected Results
Typical: E falls by ~4 mV per 10 K rise; dE/dT ~ -4 x 10^-4 V/K.
Worked Stoichiometric Calculations
Problem: If dE/dT = -4.0 x 10^-4 V/K for the Daniell cell (n = 2), calculate DeltaSdeg.
Working: DeltaSdeg = nF(dE/dT) = 2 x 96485 x (-4.0 x 10^-4) = -77.2 J/(mol K), about -77 J/(mol K).
Safety Precautions & Hazard Control
- Keep both half-cells at the same temperature.
- Do not overheat; evaporation changes concentrations.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Collect metal salt solutions in the heavy-metal waste container.
Viva Voce Oral Defense Questions & Answers
Q: What does the sign of dE/dT tell you?
A: Its sign equals the sign of DeltaS for the cell reaction: negative here means entropy decreases (aqueous Zn2+ is more ordered than Cu2+).
Q: Why must both half-cells be at the same temperature?
A: A temperature difference creates a thermoelectric (Seebeck) voltage that contaminates the chemical EMF.