CHEMVEN

Verification of the Nernst Equation with a Copper Electrode

To verify the Nernst equation by measuring Cu2+/Cu electrode potential at various Cu2+ concentrations.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To verify the Nernst equation by measuring Cu2+/Cu electrode potential at various Cu2+ concentrations.

Theoretical Foundations

For Cu2+ + 2e- -> Cu, E = Edeg + (0.0591/2) log[Cu2+] at 25 C. A plot of E versus log[Cu2+] should be a straight line of slope 0.0591/2 = 0.0296 V per decade, intercepting Edeg = +0.34 V at [Cu2+] = 1 M.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Copper strips
  • 100 mL beakers
  • Saturated calomel electrode
  • Digital voltmeter
  • Salt bridge
  • Volumetric flasks
  • Pipettes
  • Connecting wires

Chemical Reagents

  • CuSO4 stock solution (1.0 M)
  • Saturated KCl (for calomel)
  • Distilled water

Step-by-Step Practical Procedure

  1. Prepare CuSO4 solutions of 1.0, 0.10, 0.010 and 0.0010 M by serial dilution.
  2. Set up Cu|Cu2+(c) against the calomel electrode via a salt bridge.
  3. Measure the cell EMF for each concentration.
  4. Convert each reading to E(Cu2+/Cu) vs SHE by adding 0.242 V.
  5. Plot E versus log[Cu2+]; find the slope and intercept.

Observations & Expected Results

Typical E values (vs SHE): 0.34, 0.31, 0.28, 0.25 V for 1.0 to 0.001 M. Plot is linear with slope ~29-30 mV/decade.

Worked Stoichiometric Calculations

Problem: Calculate E(Cu2+/Cu) at [Cu2+] = 0.0010 M and 25 C (Edeg = +0.34 V).

Working: E = 0.34 + (0.0591/2) log(0.001) = 0.34 + 0.02955 x (-3) = 0.34 - 0.0887 = 0.251 V, about 0.25 V.

Safety Precautions & Hazard Control

  • Prepare dilutions accurately; the log scale magnifies errors.
  • Keep the calomel electrode at constant temperature.
  • Rinse the Cu electrode between solutions.

Waste Disposal Protocol

Collect CuSO4 solutions in the heavy-metal waste container.

Viva Voce Oral Defense Questions & Answers

Q: What slope do you expect for a one-electron couple like Ag+/Ag?

A: 0.0591 V per decade of concentration, since slope = 0.0591/n with n = 1.

Q: Why does the plot deviate at very low concentrations?

A: Activity coefficients deviate from 1 and impurities/dissolved oxygen contribute relatively more, so concentration no longer equals activity.

← Back to Experiments Directory