CHEMVEN

Building the Electrochemical Series by Displacement Reactions

To arrange metals in order of reactivity from displacement reactions.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To arrange metals in order of reactivity from displacement reactions.

Theoretical Foundations

A more reactive metal (more negative Edeg) displaces a less reactive metal from its salt solution: e.g. Zn + Cu2+ -> Zn2+ + Cu is spontaneous because Edegcell = +1.10 V. No reaction occurs in the reverse direction. A matrix of metal/solution tests reveals the full reactivity order.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Metal strips: Mg, Zn, Fe, Cu, Ag
  • Test tubes and rack
  • Sandpaper
  • Forceps

Chemical Reagents

  • MgSO4 (0.5 M)
  • ZnSO4 (0.5 M)
  • FeSO4 (0.5 M)
  • CuSO4 (0.5 M)
  • AgNO3 (0.1 M)

Step-by-Step Practical Procedure

  1. Clean all metal strips with sandpaper.
  2. Place each metal strip into each of the five salt solutions (25 combinations).
  3. Observe for 5 minutes: look for metal deposition, colour change or gas.
  4. Record + (reaction) or - (no reaction) in a matrix.
  5. Deduce the reactivity order from the matrix.

Observations & Expected Results

Mg displaces all others; Zn displaces Fe, Cu, Ag; Fe displaces Cu, Ag; Cu displaces Ag; Ag displaces none. Order: Mg > Zn > Fe > Cu > Ag.

Worked Stoichiometric Calculations

Problem: Use Edeg values (Mg -2.37, Zn -0.76, Fe -0.44, Cu +0.34, Ag +0.80 V) to calculate Edegcell for Zn displacing Cu2+ and for Cu displacing Zn2+.

Working: Zn + Cu2+ -> Zn2+ + Cu: Edeg = 0.34 - (-0.76) = +1.10 V (spontaneous). Cu + Zn2+ -> Cu2+ + Zn: Edeg = -0.76 - 0.34 = -1.10 V (non-spontaneous). Hence Zn displaces Cu2+ but not vice versa.

Safety Precautions & Hazard Control

  • AgNO3 stains skin and clothes; wear gloves.
  • Mg reacts vigorously - use small pieces.
  • Wipe up any spills immediately and keep the bench dry.

Waste Disposal Protocol

Collect all solutions in the heavy-metal waste container.

Viva Voce Oral Defense Questions & Answers

Q: Why does iron displace copper from CuSO4 but copper does not displace iron from FeSO4?

A: Fe has the more negative Edeg (-0.44 V vs +0.34 V), so Fe oxidation coupled with Cu2+ reduction gives a positive Ecell, while the reverse gives a negative Ecell.

Q: Where would hydrogen fit in this series?

A: Between Fe (-0.44 V) and Cu (+0.34 V): metals above H2 (Mg, Zn, Fe) liberate H2 from dilute acids, while Cu and Ag do not.