Function of the Salt Bridge in a Galvanic Cell
To demonstrate that a galvanic cell cannot sustain current without a salt bridge.
Theoretical Foundations
A galvanic cell needs two conduction paths: electrons through the external wire and ions through the internal electrolyte. Without a salt bridge, charge builds up (Zn2+ excess at the anode, SO4(2-) excess at the cathode), the cell polarises, and current stops almost immediately.
Required Apparatus & Chemicals
Laboratory Apparatus
- Zinc and copper strips
- Two 100 mL beakers
- Salt bridge (KNO3 in agar)
- Digital voltmeter or galvanometer
- Connecting wires
- Filter paper strip (alternative bridge)
- Measuring cylinder
Chemical Reagents
- Zinc sulphate solution (1.0 M)
- Copper(II) sulphate solution (1.0 M)
- Potassium nitrate (for salt bridge)
Step-by-Step Practical Procedure
- Set up the Zn and Cu half-cells as in the Daniell cell but WITHOUT the salt bridge.
- Connect the electrodes to the voltmeter and note the reading and how it changes with time.
- Insert the salt bridge and record the new steady reading.
- Remove the bridge again and observe the fall in reading.
- Repeat using a filter-paper strip soaked in KNO3 as a makeshift bridge.
Observations & Expected Results
Without the bridge the EMF collapses within seconds to near zero; with the bridge it holds steady near 1.10 V. The filter-paper bridge works but gives a slightly lower reading.
Worked Stoichiometric Calculations
Problem: If the cell delivers 0.05 A for 10 minutes through the bridge, what mass of Zn dissolves? (M(Zn) = 65.4 g/mol)
Working: Q = 0.05 x 600 = 30 C. Moles of electrons = 30/96485 = 3.11 x 10^-4 mol. Zn dissolves as Zn -> Zn2+ + 2e-, so moles Zn = 1.55 x 10^-4 mol. Mass = 1.55 x 10^-4 x 65.4 = 0.0102 g, about 10 mg.
Safety Precautions & Hazard Control
- Do not short-circuit the electrodes directly.
- Keep electrolytes from mixing when inserting the bridge.
- Wear gloves when handling CuSO4.
Waste Disposal Protocol
Return electrolyte solutions to the heavy-metal waste bottle.
Viva Voce Oral Defense Questions & Answers
Q: Can the salt bridge be replaced by a metal wire?
A: No. A metal wire conducts electrons but the internal circuit needs ion movement to balance charge; a wire would also short the cell.
Q: Why is KNO3 used in the salt bridge?
A: K+ and NO3- have nearly equal ionic mobilities, so the liquid junction potential is minimised, and neither ion reacts with the cell electrolytes.