CHEMVEN

Constructing the Daniell Cell and Measuring its EMF

To construct a Zn-Cu Daniell cell and measure its electromotive force.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To construct a Zn-Cu Daniell cell and measure its electromotive force.

Theoretical Foundations

A galvanic cell converts chemical energy into electrical energy. In the Daniell cell, zinc is oxidised (anode, Zn -> Zn2+ + 2e-) and Cu2+ is reduced (cathode, Cu2+ + 2e- -> Cu). The standard EMF is Edegcell = Edegcathode - Edeganode = 0.34 - (-0.76) = 1.10 V at 25 C.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Zinc strip electrode
  • Copper strip electrode
  • Two 100 mL beakers
  • Salt bridge (KNO3 in agar)
  • Digital voltmeter
  • Connecting wires with crocodile clips
  • Sandpaper
  • Measuring cylinder

Chemical Reagents

  • Zinc sulphate solution (1.0 M)
  • Copper(II) sulphate solution (1.0 M)
  • Potassium nitrate (for salt bridge)

Step-by-Step Practical Procedure

  1. Clean the Zn and Cu strips with sandpaper and rinse with distilled water.
  2. Pour 50 mL of 1.0 M ZnSO4 into one beaker and 50 mL of 1.0 M CuSO4 into the other.
  3. Place the Zn strip in ZnSO4 and the Cu strip in CuSO4 solution.
  4. Connect the two beakers with the salt bridge, dipping one end in each solution.
  5. Connect the electrodes to the voltmeter: Cu to the positive terminal, Zn to the negative terminal.
  6. Record the steady EMF reading.
  7. Reverse the leads and confirm the sign reverses.

Observations & Expected Results

Typical voltmeter reading: 1.08-1.10 V with Cu positive. The Zn strip slowly loses mass while a fresh copper deposit appears on the Cu strip.

Worked Stoichiometric Calculations

Problem: Given Edeg(Zn2+/Zn) = -0.76 V and Edeg(Cu2+/Cu) = +0.34 V, calculate Edegcell and the standard free energy change for the cell reaction (n = 2, F = 96485 C/mol).

Working: Edegcell = 0.34 - (-0.76) = 1.10 V. DeltaGdeg = -nFEdeg = -2 x 96485 x 1.10 = -212,267 J/mol, about -212 kJ/mol. The negative sign confirms the reaction is spontaneous.

Safety Precautions & Hazard Control

  • Clean electrodes before use for good electrical contact.
  • Do not let the two electrolyte solutions mix.
  • Keep the salt bridge ends fully immersed.
  • Handle CuSO4 solution with gloves; it stains skin.

Waste Disposal Protocol

Collect CuSO4 and ZnSO4 solutions in the labelled heavy-metal waste container; do not pour down the drain.

Viva Voce Oral Defense Questions & Answers

Q: Why is the salt bridge needed?

A: It completes the circuit by allowing ion migration, maintaining electrical neutrality in both half-cells without direct mixing of electrolytes.

Q: Why is the measured EMF slightly less than 1.10 V?

A: Because of activity effects, liquid junction potentials, and the internal resistance of the cell drawing a tiny current through the voltmeter.

← Back to Experiments Directory