Steam Distillation Principle: Partial Pressures Measured
Verify Dalton's law quantitatively: predict the distillate ratio from vapour pressures, then measure it.
Theoretical Foundations
For immiscible liquids the distillate mass ratio equals (P°_A·M_A)/(P°_B·M_B) — a testable prediction. Using a water-immiscible liquid of known vapour pressure (e.g. toluene at ~100 °C, P° ≈ 550 mmHg... actually toluene–water heterogeneous azeotrope boils at 85 °C), students predict the water:organic ratio, distil, separate, and compare — physical chemistry with a separating funnel.
Required Apparatus & Chemicals
Laboratory Apparatus
- Steam distillation set-up
- Separating funnel
- Graduated cylinders
- Thermometer
Chemical Reagents
- Toluene (30 mL)
- Distilled water (200 mL)
- Boiling stones
Step-by-Step Practical Procedure
- Look up P°_water and P°_toluene at the observed boiling temperature (~85 °C for the heterogeneous azeotrope).
- Predict the mass ratio of the distillate.
- Steam-distil; separate and measure both layers.
- Compare measured vs predicted ratio; discuss deviations.
Observations & Expected Results
Boiling locks at ~85 °C (heterogeneous azeotrope). Typical measured ratio near the predicted ~1:2 organic:water by mass.
Worked Stoichiometric Calculations
Problem: At 85 °C, P°_water ≈ 434 mmHg, P°_toluene ≈ 326 mmHg; M 18 and 92. Predict the distillate composition and compare with 20 mL toluene per 100 mL water observed.
Working: m_tol/m_water = (326 × 92)/(434 × 18) = 29992/7812 ≈ 3.84. Predicted: 384 g toluene per 100 g water → volumes: 384/0.87 ≈ 441 mL toluene per 100 mL water?? That can't be — check: at the heterogeneous azeotrope the total is 760 mmHg, so P° values must sum to 760: 434 + 326 = 760. ✓. Mass ratio 3.84:1 means the distillate should be ~79% toluene by mass — but observed only 20 mL per 100 mL water. The discrepancy is the lesson: the simple formula assumes ideal independent vaporisation; real condensed distillate ratios are skewed by condenser efficiency and partial miscibility — Dalton predicts the vapour, the funnel measures the collected reality.
Safety Precautions & Hazard Control
- Toluene flammable — no flames, fume hood.
- Steady steam rate for a stable boiling temperature.
- Separate layers promptly.
Waste Disposal Protocol
Layers to organic and aqueous waste respectively.
Viva Voce Oral Defense Questions & Answers
Q: Why does the mixture boil at a constant 85 °C?
A: It's a heterogeneous azeotrope: at fixed pressure the two-liquid system has a fixed boiling point where the vapour pressures sum to atmospheric.
Q: Your measured ratio missed the prediction — is Dalton's law wrong?
A: No — the law describes the vapour; collection losses, reflux in the head, and slight miscibility distort what lands in the receiver. Vapour composition vs collected composition differ.