CHEMVEN

Boiling-Point Purity Check: Distilling Toluene

Use the boiling range during distillation as a purity criterion for toluene.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: Use the boiling range during distillation as a purity criterion for toluene.

Theoretical Foundations

A pure liquid boils at a constant temperature (at fixed pressure): the entire sample converts at its characteristic vapour pressure. Impurities broaden the boiling range — volatile impurities depress the initial bp, non-volatiles raise it progressively. A boiling range under ~1 °C during steady distillation is the distillation analogue of a sharp melting point.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Distillation set-up
  • Thermometer
  • Heating mantle
  • Retort stand and clamps

Chemical Reagents

  • Toluene, technical grade (50 mL)
  • Boiling stones
  • Cold water (for the condenser)

Step-by-Step Practical Procedure

  1. Distil 50 mL technical toluene at a steady rate (~1 drop per second).
  2. Record head temperature for each 5 mL of distillate.
  3. Plot temperature vs volume; identify forerun, main fraction, and tail.
  4. Report the boiling range of the main fraction.

Observations & Expected Results

Forerun a few mL below 110 °C, then a long plateau at 110–111 °C (pure toluene bp 110.6 °C). A rising tail indicates high-boiling impurities left behind.

Worked Stoichiometric Calculations

Problem: The main fraction (38 mL) boiled over 110.2–110.9 °C. Is this acceptable as pure toluene, and what does the 3 mL forerun at 105–109 °C represent?

Working: Yes — a 0.7 °C range centred on 110.6 °C is excellent. The forerun is lower-boiling impurities (e.g. benzene, water azeotrope) that distilled first; discarding it is what sharpened the main fraction.

Safety Precautions & Hazard Control

  • Toluene is flammable and harmful by inhalation — fume hood.
  • Steady heating: surging gives a false broad range.
  • Never distil to dryness.

Waste Disposal Protocol

Forerun and residue to organic waste.

Viva Voce Oral Defense Questions & Answers

Q: Why does the distillation rate affect the observed boiling range?

A: Too fast and the thermometer lags while impure vapour fractions mix — a slow steady rate lets each fraction register its true temperature.

Q: A pure liquid boiled at 109–113 °C — pure or not?

A: Not pure: a 4 °C range means volatile and high-boiling impurities are both present; pure toluene holds within ~1 °C.