Boiling-Point Purity Check: Distilling Toluene
Use the boiling range during distillation as a purity criterion for toluene.
Theoretical Foundations
A pure liquid boils at a constant temperature (at fixed pressure): the entire sample converts at its characteristic vapour pressure. Impurities broaden the boiling range — volatile impurities depress the initial bp, non-volatiles raise it progressively. A boiling range under ~1 °C during steady distillation is the distillation analogue of a sharp melting point.
Required Apparatus & Chemicals
Laboratory Apparatus
- Distillation set-up
- Thermometer
- Heating mantle
- Retort stand and clamps
Chemical Reagents
- Toluene, technical grade (50 mL)
- Boiling stones
- Cold water (for the condenser)
Step-by-Step Practical Procedure
- Distil 50 mL technical toluene at a steady rate (~1 drop per second).
- Record head temperature for each 5 mL of distillate.
- Plot temperature vs volume; identify forerun, main fraction, and tail.
- Report the boiling range of the main fraction.
Observations & Expected Results
Forerun a few mL below 110 °C, then a long plateau at 110–111 °C (pure toluene bp 110.6 °C). A rising tail indicates high-boiling impurities left behind.
Worked Stoichiometric Calculations
Problem: The main fraction (38 mL) boiled over 110.2–110.9 °C. Is this acceptable as pure toluene, and what does the 3 mL forerun at 105–109 °C represent?
Working: Yes — a 0.7 °C range centred on 110.6 °C is excellent. The forerun is lower-boiling impurities (e.g. benzene, water azeotrope) that distilled first; discarding it is what sharpened the main fraction.
Safety Precautions & Hazard Control
- Toluene is flammable and harmful by inhalation — fume hood.
- Steady heating: surging gives a false broad range.
- Never distil to dryness.
Waste Disposal Protocol
Forerun and residue to organic waste.
Viva Voce Oral Defense Questions & Answers
Q: Why does the distillation rate affect the observed boiling range?
A: Too fast and the thermometer lags while impure vapour fractions mix — a slow steady rate lets each fraction register its true temperature.
Q: A pure liquid boiled at 109–113 °C — pure or not?
A: Not pure: a 4 °C range means volatile and high-boiling impurities are both present; pure toluene holds within ~1 °C.