Thin-Layer Chromatography: Purity Check of an Organic Sample

To check the purity of an organic sample and identify components by TLC.

Level: UniversitySafety: SafeTime: 60 min
Aim of Experiment: To check the purity of an organic sample and identify components by TLC.

Theoretical Foundations

In TLC, compounds separate by differential adsorption on silica: polar compounds adsorb strongly (low Rf), non-polar travel far (high Rf). A pure compound gives one spot; impurities give extra spots. Rf = distance moved by spot / distance moved by solvent front, compared with authentic standards.

Required Apparatus & Chemicals

Laboratory Apparatus

  • TLC plates (silica)
  • Developing chamber
  • Capillary spotters
  • UV lamp
  • Ruler
  • Iodine chamber (optional)

Chemical Reagents

  • Sample (e.g. recrystallised acetanilide)
  • Authentic acetanilide standard
  • Eluent: ethyl acetate/hexane 1:2
  • Iodine crystals (visualisation)

Step-by-Step Practical Procedure

  1. Spot the sample and the authentic standard side by side near the plate base.
  2. Develop in the saturated chamber until the front nears the top.
  3. Mark the solvent front immediately on removal.
  4. Visualise under UV and in iodine vapour.
  5. Compare spot counts and Rf values.

Observations & Expected Results

Pure sample: single spot, Rf identical to standard (e.g. 0.45). Impure sample: two or more spots.

Worked Stoichiometric Calculations

Problem: A spot travelled 3.6 cm; the solvent front travelled 8.0 cm. Calculate Rf and comment if the standard also gives 0.45.

Working: Rf = 3.6/8.0 = 0.45. Identical Rf to the authentic standard supports (but alone does not prove) identity; co-spotting confirms it.

Safety Precautions & Hazard Control

  • Do not let the solvent level cover the spots.
  • Saturate the chamber with eluent vapour for straight fronts.
  • Mark the front before it evaporates.

Waste Disposal Protocol

Used plates to solid waste; eluent to organic solvent waste.

Viva Voce Oral Defense Questions & Answers

Q: What does a single spot prove?

A: That the sample behaves as one compound in this solvent system; a second system is needed for stronger proof of purity.

Q: Why compare with an authentic standard?

A: Identical Rf in the same run suggests identity; co-spotting (mixed spot stays single) confirms it.

Q: Why does a polar impurity stay near the baseline?

A: It adsorbs strongly to the polar silica stationary phase and is poorly eluted by the mobile phase.