Molecular Weight of a Volatile Liquid: Victor Meyer Method
To determine the molecular weight of a volatile organic liquid by Victor Meyer's method.
Theoretical Foundations
A weighed sample is vaporised in a hot tube; the vapour displaces an equal volume of air collected over water. By the gas laws, MW = wRT/PV (at STP, MW = w x 22400/V in mL). The method suits liquids boiling below about 250 C.
Required Apparatus & Chemicals
Laboratory Apparatus
- Victor Meyer apparatus
- Water bath or oil bath
- Eudiometer tube
- Small glass bulb with sample
- Thermometer
- Barometer
Chemical Reagents
- Volatile liquid, e.g. chloroform (~0.24 g in sealed bulb)
- Water for the trough
- Ice (for cooling the eudiometer)
Step-by-Step Practical Procedure
- Set up the Victor Meyer tube in the heating bath and let the temperature stabilise.
- Fill the eudiometer with water and invert it over the delivery tube.
- Drop the weighed sample bulb into the hot tube and seal quickly.
- Collect the displaced air; let the eudiometer cool to room temperature.
- Equalise water levels, read the air volume, note T and P, and calculate MW.
Observations & Expected Results
0.239 g chloroform displaces about 45.0 mL of air at STP, giving MW ~119 (actual 119.5).
Worked Stoichiometric Calculations
Problem: 0.239 g of a volatile liquid displaced 45.0 mL of dry air at STP. Calculate its molecular weight.
Working: Moles of air = moles of vapour = 45.0/22400 = 0.002009 mol. MW = 0.239/0.002009 = 119.0 g/mol, consistent with chloroform (119.5).
Safety Precautions & Hazard Control
- The vaporisation temperature must exceed the liquid's bp but not decompose it.
- Correct the collected volume for aqueous tension if collected over water.
- Seal the apparatus quickly after dropping the bulb to avoid vapour loss.
Waste Disposal Protocol
Collect condensed organic vapour/liquid in the solvent waste bottle.
Viva Voce Oral Defense Questions & Answers
Q: State the principle of Victor Meyer's method in one line.
A: Equal volumes of gases at the same T and P contain equal numbers of molecules, so the displaced air volume gives the moles of vaporised sample.
Q: Why must the bath be hotter than the sample's boiling point?
A: To vaporise the sample instantly and completely; otherwise liquid remains and the displaced volume is too small.
Q: Which liquids are unsuitable for this method?
A: High-boiling (>250 C), thermally unstable, or non-volatile liquids.