Melting Point Determination: Capillary Tube Method
To determine the melting point of a given organic solid using the capillary tube method.
Theoretical Foundations
A pure crystalline solid melts sharply over 1-2 C. The capillary method heats a packed sample in a liquid bath (oil or H2SO4) beside a thermometer; the temperature at which the solid collapses to a clear liquid is the melting point. Impurities depress and broaden the range (eutectic behaviour).
Required Apparatus & Chemicals
Laboratory Apparatus
- Melting point apparatus or Thiele tube
- Capillary tubes (sealed at one end)
- Thermometer (0-250 C)
- Spatula
- Watch glass
Chemical Reagents
- Organic solid sample (e.g. urea, ~0.1 g)
- Liquid paraffin or conc. H2SO4 (bath fluid, ~50 mL)
- Authentic reference sample (for comparison)
Step-by-Step Practical Procedure
- Grind the sample to a fine powder on a watch glass.
- Fill a sealed capillary to 2-3 mm by tapping the open end into the powder.
- Attach the capillary to the thermometer bulb with a rubber band.
- Heat the bath slowly, about 2 C per minute near the expected mp.
- Record the temperature when the solid first collapses and when it becomes fully clear.
Observations & Expected Results
Pure urea melts at 132-133 C. A sharp range of 1-2 C indicates purity; a broad/depressed range indicates impurity.
Worked Stoichiometric Calculations
Problem: A sample shows mp 118-124 C while the pure compound melts at 132-133 C. What does this indicate, and estimate the purity implication?
Working: The depressed (14 C lower) and broadened (6 C range) melting point indicates the sample is impure. Impurities disrupt the crystal lattice, lowering and broadening the mp (freezing-point depression). The sample needs recrystallisation; a pure sample should melt within 1-2 C of the literature value.
Safety Precautions & Hazard Control
- Heat slowly near the melting point to avoid overshooting.
- Do not reuse capillary tubes.
- Keep the bath fluid below its smoke point; handle hot apparatus with care.
Waste Disposal Protocol
Cool the bath fluid, then dispose of it and used capillaries in the solid chemical waste container.
Viva Voce Oral Defense Questions & Answers
Q: Why does an impure solid melt lower and over a range?
A: Impurities disrupt the regular crystal lattice and act like a solute, causing freezing-point depression and eutectic melting over a temperature range.
Q: Why is slow heating essential near the mp?
A: Fast heating creates a lag between bath and sample temperature, so the recorded thermometer reading overshoots the true melting point.
Q: What is the purpose of sealing one end of the capillary?
A: To hold the powdered sample in place so it does not fall out or mix with the bath fluid during heating.