CHEMVEN

Chlorine from Potassium Permanganate and Hydrochloric Acid

To prepare chlorine gas rapidly by the action of concentrated hydrochloric acid on potassium permanganate.

Level: UniversitySafety: Advanced lab onlyTime: 30 min
Aim of Experiment: To prepare chlorine gas rapidly by the action of concentrated hydrochloric acid on potassium permanganate.

Theoretical Foundations

Permanganate oxidizes chloride in the cold: 2KMnO4 + 16HCl(conc) → 2KCl + 2MnCl2 + 5Cl2↑ + 8H2O. No heating is needed, making this the quickest laboratory source of chlorine for tests.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conical flask
  • Dropping funnel
  • Delivery tube
  • Wash bottle
  • Gas jars
  • Fume cupboard

Chemical Reagents

  • Potassium permanganate, KMnO4 (15.80 g)
  • Concentrated hydrochloric acid (80 mL)
  • Distilled water (wash bottle)

Step-by-Step Practical Procedure

  1. Place 15.80 g KMnO4 in a conical flask in a fume cupboard.
  2. Fit a dropping funnel with 80 mL concentrated HCl and a delivery tube.
  3. Add the acid dropwise; chlorine evolves vigorously in the cold.
  4. Pass the gas through a water wash bottle.
  5. Collect 3–4 jars by upward displacement of air.
  6. Test with moist starch-iodide paper.

Observations & Expected Results

Vigorous greenish-yellow gas evolution; typical collection 3–4 L.

Worked Stoichiometric Calculations

Problem: 15.80 g KMnO4 (M = 158.03) reacts with excess concentrated HCl. Calculate the theoretical STP volume of Cl2 evolved.

Working: Moles KMnO4 = 15.80/158.03 = 0.100 mol. Two moles give 5 mol Cl2, so 0.100 mol gives 0.250 mol Cl2. Volume at STP = 0.250 × 22.4 = 5.60 L (mass 17.7 g).

Safety Precautions & Hazard Control

  • Chlorine is toxic; fume cupboard mandatory.
  • Add acid dropwise to control the vigorous reaction.
  • Do not use sulfuric acid here (no chloride to oxidize).
  • Keep away from ammonia.

Waste Disposal Protocol

Manganese chloride residue to inorganic waste; excess Cl2 absorbed in NaOH.

Viva Voce Oral Defense Questions & Answers

Q: Why is no heating needed?

A: Permanganate is a strong enough oxidizer to oxidize Cl− in the cold.

Q: What are the oxidation state changes?

A: Mn(VII) → Mn(II); Cl(−) → Cl(0).

Q: Why must the acid be concentrated?

A: High Cl− concentration and acidity drive the oxidation.

← Back to Experiments Directory