Qualitative Analysis of Brass: Copper and Zinc
Dissolve a brass sample and confirm its two major components, Cu and Zn.
Theoretical Foundations
Brass (~60–70% Cu, ~30–40% Zn) dissolves in dilute HNO₃: Cu + 4HNO₃ → Cu(NO₃)₂ + 2NO₂ + 2H₂O; Zn similarly. Making the solution ammoniacal and adding DMG-free tests: Cu²⁺ → deep-blue [Cu(NH₃)₄]²⁺; Zn²⁺ → white K₂Zn₃[Fe(CN)₆]₂ with ferrocyanide after acidification. A real-alloy application of the schemes.
Required Apparatus & Chemicals
Laboratory Apparatus
- Beaker
- Test tubes
- Fume cupboard
- Filter paper
Chemical Reagents
- Brass turnings/filings
- Dilute HNO₃ (~4 M)
- Aqueous NH₃
- K₄[Fe(CN)₆]
- Dilute H₂SO₄
Step-by-Step Practical Procedure
- Dissolve ~0.5 g brass in warm dilute HNO₃ in the fume cupboard (brown NO₂).
- Dilute; make ammoniacal: deep-blue solution (Cu confirmed).
- Acidify a portion; add ferrocyanide: white precipitate (Zn confirmed).
- Optional: estimate Cu:Zn roughly from colour intensity vs standards.
- Report the alloy composition qualitatively.
Observations & Expected Results
Blue solution (Cu); white ferrocyanide precipitate (Zn).
Worked Stoichiometric Calculations
Problem: 0.50 g brass (~65% Cu) dissolved and made to 100 mL. [Cu²⁺]? (illustrative)
Working: 0.325 g Cu = 0.0051 mol → 0.051 M — plenty for confirmatory tests.
Safety Precautions & Hazard Control
- NO₂ evolution — fume cupboard essential.
- HNO₃ corrosive.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Alloy digest to heavy-metal waste.
Viva Voce Oral Defense Questions & Answers
Q: Why HNO₃ and not HCl for dissolving brass?
A: HCl alone cannot oxidise copper metal; HNO₃'s oxidising power is needed.
Q: How would you detect leaded brass?
A: Dilute H₂SO₄ gives white PbSO₄ — lead is a common brass additive.