CHEMVEN

Analysis in Presence of Interfering Radicals: Putting It Together

Analyse a mixture containing an interfering radical (phosphate) plus Group III/IV cations using the full clean-up scheme.

Level: UniversitySafety: Advanced lab onlyTime: 2 h
Aim of Experiment: Analyse a mixture containing an interfering radical (phosphate) plus Group III/IV cations using the full clean-up scheme.

Theoretical Foundations

The complete interference workflow: (1) preliminary anion tests identify PO₄³⁻/C₂O₄²⁻/F⁻/BO₃³⁻; (2) targeted removal (zirconyl nitrate / ignition / H₂SO₄ fuming); (3) verification of removal (molybdate negative); (4) standard cation scheme. This experiment integrates 083–085 with the group separations.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes (10)
  • Crucible + burner
  • Filter papers + funnels
  • Fume cupboard

Chemical Reagents

  • Unknown (cations + phosphate spike)
  • Zirconyl nitrate
  • Conc. HNO₃
  • Ammonium molybdate
  • NH₄Cl
  • Aqueous NH₃
  • NaOH + H₂O₂ (peroxide separation)
  • Standard Group III/IV reagents

Step-by-Step Practical Procedure

  1. Run preliminary tests: identify the interfering radical (molybdate yellow = phosphate).
  2. Remove phosphate with zirconyl nitrate in HNO₃; filter; verify removal.
  3. Run Group III precipitation (NH₄Cl/NH₄OH) on the filtrate.
  4. Separate Fe/Al/Cr via NaOH/H₂O₂; confirm each.
  5. Analyse the Group III filtrate for Group IV cations.
  6. Report cations with evidence and note the interference handled.

Observations & Expected Results

Clean group separations only after the interference is removed — the control without removal fails.

Worked Stoichiometric Calculations

Problem: Why verify removal before proceeding?

Working: Residual phosphate re-precipitates Group III metals downstream; a negative molybdate test is the gate check.

Safety Precautions & Hazard Control

  • Full scheme hazards: acids, H₂S if used, chromate — fume cupboard, goggles, gloves.
  • Wear safety goggles and a lab coat throughout the experiment.
  • Tie back long hair and secure loose clothing before starting.

Waste Disposal Protocol

Segregate phosphate/zirconium, chromate and heavy-metal wastes.

Viva Voce Oral Defense Questions & Answers

Q: What is the most common exam trap here?

A: Forgetting that phosphate must be removed before Group III — the scheme silently fails otherwise.

Q: How do you choose the removal method?

A: Match it to the radical: ignition for oxalate, zirconyl for phosphate, fuming for fluoride/borate.

← Back to Experiments Directory