Thiosulphate Test: Silver Nitrate and Iodine
Detect S₂O₃²⁻ by the white→black Ag₂S₂O₃ sequence and iodine decolourisation.
Theoretical Foundations
Ag⁺ + S₂O₃²⁻ → white Ag₂S₂O₃, which hydrolyses on standing/boiling to black Ag₂S: Ag₂S₂O₃ + H₂O → Ag₂S + 2H⁺ + SO₄²⁻. Thiosulphate decolourises iodine: I₂ + 2S₂O₃²⁻ → 2I⁻ + S₄O₆²⁻ — the iodometric reaction. BaCl₂ gives no precipitate (cf. sulphate).
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes
- Water bath
- Dropper
- Test-tube rack
Chemical Reagents
- Sodium thiosulphate (~0.1 M)
- Silver nitrate (~0.1 M)
- Iodine solution (dilute)
- Starch (optional)
- Barium chloride
Step-by-Step Practical Procedure
- Add AgNO₃: white precipitate, turning yellow then black on standing/boiling.
- Add iodine solution: brown colour discharged (add starch — blue disappears).
- BaCl₂ test: no precipitate (distinguishes from sulphate).
- Acidify a portion: milky sulphur + SO₂ (thiosulphate disproportionates).
Observations & Expected Results
White→black silver precipitate; iodine decolourised; sulphur milkiness with acid.
Worked Stoichiometric Calculations
Problem: I₂ + 2S₂O₃²⁻ → 2I⁻ + S₄O₆²⁻. What is thiosulphate's n-factor here?
Working: 2S₂O₃²⁻ → S₄O₆²⁻ + 2e⁻, so 1 per thiosulphate ion.
Safety Precautions & Hazard Control
- Silver stains — gloves.
- Acid + thiosulphate releases SO₂ — ventilate.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Silver residues to recovery; sulphur waste to chemical waste.
Viva Voce Oral Defense Questions & Answers
Q: Why does the white precipitate blacken?
A: Hydrolysis to Ag₂S (black) — diagnostic of thiosulphate vs chloride.
Q: How is thiosulphate distinguished from sulphite?
A: Both reduce iodine, but only thiosulphate gives the white→black silver sequence.