CHEMVEN

Nitrate Test: The Brown Ring

Detect NO₃⁻ by the brown-ring test with FeSO₄ and concentrated H₂SO₄.

Level: UniversitySafety: Needs supervisionTime: 35 min
Aim of Experiment: Detect NO₃⁻ by the brown-ring test with FeSO₄ and concentrated H₂SO₄.

Theoretical Foundations

Layering conc. H₂SO₄ under a mixture of nitrate + FeSO₄ gives a brown ring of [Fe(H₂O)₅(NO)]²⁺ at the interface: NO₃⁻ + 3Fe²⁺ + 4H⁺ → NO + 3Fe³⁺ + 2H₂O, then Fe²⁺ + NO → [Fe(NO)]²⁺ (brown). Nitrite also gives colour but is removed beforehand with urea/sulphamic acid.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes
  • Dropper
  • Test-tube rack
  • Test-tube holder

Chemical Reagents

  • Potassium nitrate (~0.1 M)
  • Fresh iron(II) sulphate (~0.2 M)
  • Concentrated H₂SO₄
  • Urea (nitrite removal, if needed)

Step-by-Step Practical Procedure

  1. Mix equal volumes of nitrate solution and fresh FeSO₄.
  2. Tilt the tube; pour conc. H₂SO₄ slowly down the side to form a lower layer.
  3. A brown ring forms at the junction within minutes.
  4. Run a nitrite control (brown throughout, not a ring) and a blank.

Observations & Expected Results

Sharp brown ring at the acid interface = nitrate.

Worked Stoichiometric Calculations

Problem: Why must FeSO₄ be fresh?

Working: Fe²⁺ air-oxidises to Fe³⁺, which cannot reduce NO₃⁻ to NO — stale reagent gives false negatives.

Safety Precautions & Hazard Control

  • Conc. H₂SO₄ — severe burns hazard; pour slowly, goggles, lab coat.
  • Nitrite interference — destroy with urea first if present.
  • Wear safety goggles and a lab coat throughout the experiment.

Waste Disposal Protocol

Acidic iron waste neutralised, then to chemical waste.

Viva Voce Oral Defense Questions & Answers

Q: What is the brown ring chemically?

A: [Fe(H₂O)₅(NO)]²⁺ — an Fe(I)–NO⁺ nitrosyl complex.

Q: Why layer instead of mixing?

A: The ring needs the concentration gradient at the interface; mixing disperses the colour.

← Back to Experiments Directory