CHEMVEN

Removal of Ammonium Before Group III: The Zero-Group Boil

Remove NH₄⁺ by boiling with NaOH before Group III, and prove its absence afterwards.

Level: UniversitySafety: Needs supervisionTime: 40 min
Aim of Experiment: Remove NH₄⁺ by boiling with NaOH before Group III, and prove its absence afterwards.

Theoretical Foundations

NH₄⁺ interferes with Group III (it buffers the NH₄Cl/NH₄OH system and gives false cobaltinitrite tests later). Boiling the Group II filtrate with NaOH expels NH₃: NH₄⁺ + OH⁻ → NH₃↑ + H₂O. Completeness is checked with Nessler's reagent or red litmus on the vapours.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Beaker
  • Bunsen burner
  • Litmus paper
  • Dropper

Chemical Reagents

  • Group II filtrate (contains NH₄⁺)
  • Sodium hydroxide (~2 M)
  • Nessler's reagent

Step-by-Step Practical Procedure

  1. Add excess NaOH to the Group II filtrate; boil gently.
  2. Test vapours with moist red litmus — blue while NH₃ evolves.
  3. Continue boiling until litmus stays red and Nessler's test on a cooled drop is negative.
  4. Cool; the solution is now ready for Group III precipitation.

Observations & Expected Results

Litmus blue→red transition marks complete NH₄⁺ removal.

Worked Stoichiometric Calculations

Problem: Why is this step called the 'zero group'?

Working: NH₄⁺ is sometimes called the zero-group cation — it is removed before the numbered groups begin.

Safety Precautions & Hazard Control

  • Boiling NaOH — bumping hazard; add boiling chips, wear goggles.
  • NH₃ vapours — ventilate.
  • Wear safety goggles and a lab coat throughout the experiment.

Waste Disposal Protocol

Alkaline filtrate neutralised before disposal.

Viva Voce Oral Defense Questions & Answers

Q: What goes wrong if NH₄⁺ is not removed?

A: Excess NH₄⁺ flattens the NH₄Cl/NH₄OH buffer, so Group III hydroxides precipitate incompletely.

Q: How do you know boiling is complete?

A: Negative Nessler's test and no blue on red litmus.

← Back to Experiments Directory